Powerware – 9390 – 120-480 – UPS – Refurbished

Manufacturer

OEM Part Number

9390-120-480

GPS Part Number

9390-120-480

Categories

Price:

$22,900.00

Specifications
View Spec Sheet
Voltage AH/kVA Length Width Height Weight
120 kVA / 108 kW 480 V 31.6″ 31.6" 73.7" 1,030 lb
Voltage 120 kVA / 108 kW
Amp/H 480 V
Length 31.6″
Width 31.6"
Height 73.7"
Weight 1,030 lb

Refurbished UPS — Eaton/Powerware (PW9390-120/480)

480 V three-phase • True double-conversion (VFI) • 0.9 PF (108 kW) • Integrated static bypass

The Powerware 9390 120 kVA @ 480 V is a transformer-free, three-phase online UPS with an integrated static bypass and a variable DC bus.
Our refurbished units are fully reconditioned, cosmetically refreshed, and tested in the USA for dependable, ready-to-deploy service.

What you get
  • Thorough refurbishment — inspection, OEM-spec wear-parts replaced, repaint, final QA
  • Comprehensive testing — burn-in, functional verification, alarms cleared
  • Network-ready — front LCD/HMI; dual X-Slot bays (SNMP/web, Modbus/RS-485, relay)
  • Configured to order — standard 480/480 V line-ups with integrated bypass
  • U.S. warranty & support from Gruber Power Services

Technical Specifications — PW9390-120/480
Category Detail
Power & Topology 120 kVA / 108 kW; transformer-free true double-conversion (VFI) with IGBT rectifier & PWM inverter; Hot Sync™ parallel-capable; variable DC bus 432 Vdc or 480 Vdc (192–240 cells).
Input Operating input window (3-phase): 480 V → 408–528 V (nominal +10%/−15%); frequency range ±5 Hz of nominal (50/60 Hz).
Input power factor ≥0.99 (full load); input current distortion ≤5% THDi (full load).
Rectifier AC input full-load current (conductor sizing): 144 A @ 480 V. Line surge withstand: 6 kV open-circuit / 3 kA short-circuit.
Output Regulation (10–100% load) ±1%; adjustable nominal ( ±3% ): 480 V → 466–494 V.
Voltage distortion ≤1.5% THD (linear) / ≤5% THD (non-linear); transient ±5% for 100% step/removal.
Frequency ±0.01 Hz free-running; synchronous to bypass within ±0.5 Hz; slew ≤1 Hz/s.
Full-load output current: 144 A @ 480 V. Overload: 110%/10 min, 125%/30 s, 150%/10 s.
Bypass Integrated static bypass; permissible window +5% / −8% of output setting; sync bandwidth ±0.5 Hz.
Short-Circuit / AIC Coordinate breaker/withstand ratings per site one-line and configured lineup (UPS/IAC/IDC).
Battery System External Integrated Battery Cabinets (IBC-S / IBC-L); variable DC bus 432–480 Vdc at the UPS terminals.
DC current at 2.0 V/cell (end-of-discharge): 302 A dc (120 kVA). Maximum DC input breaker (continuous duty): 450 A.
Controls & Comm Front LCD/HMI with metering & event log; dual X-Slot bays (web/SNMP, Modbus/RS-485, serial); remote alarm I/O; REPO.
Physical UPS cabinet (100–160 kVA frame): 73.7″ H Ă— 35.6″ W Ă— 31.6″ D (1873 Ă— 904 Ă— 804 mm).
Installed weight: 970 lb (440 kg). Shipping weight: 1030 lb (467 kg). Point loading: 6 points @ 73 lb each.
Heat rejection at full load: 32.8 kBTU/h (480 V). Typical exhaust air: ~2000 cfm. Required clearances: 36″ front, 18″ top.
Environment Operating 0–40 °C (25 °C recommended); altitude ≤1500 m at 40 °C without derating; RH ≤95% non-condensing; acoustics ~65 dB @ 1 m.

Battery Cabinets & Options
Accessory Model Notes
Integrated Battery Cabinet IBC-S / IBC-L External runtime cabinets for 9390 (variable 432–480 Vdc bus).
Integrated Accessory Cabinet IAC-B / IAC-T / IAC-D Wrap-around maintenance bypass / tie cabinet (matching sidecar).
Integrated Distribution Cabinet IDC (100–160 kVA) Panelboard / subfeed distribution matched to 9390 line-ups.

Notes
  • All electrical and mechanical values above match the OEM single-module specifications for 9390-120/120 @ 480 V.

Why buy from Gruber
  • Professionally refurbished — Restored in our electronics engineering lab.
  • Ready to install — Line-up-and-match IBC / IAC / IDC options available.
  • Guaranteed quality — Backed by our no-hassle 1-year full replacement warranty.
Gruber Power Services