Products

Call Now For Support
1-800-658-5883

12 Volt – 60 Amp Hour YUASA Battery

Manufacturer

OEM Part Number

SWU210-12FR

GPS Part Number

58SSWU210-12FR

Categories

Price:

$250.00

Specifications
View Spec Sheet
Voltage AH/kVA Length Width Height Weight
12 Volt 60 AH 8.90" 5.31" 8.27" 40.57 lbs
Voltage 12 Volt
Amp/H 60 AH
Length 8.90"
Width 5.31"
Height 8.27"
Weight 40.57 lbs
12V 60Ah High-Temperature VRLA AGM Battery
HT X Alloy™ • 10-Year Design Life • Compact UPS & Datacenter Standby Power

The Yuasa SWU210-12FR is a compact 12-volt, valve-regulated lead-acid (VRLA) battery that uses
absorbed glass mat (AGM) technology and Yuasa’s high-temperature HT X Alloy™ to deliver long life in demanding
standby applications. With 60 Ah at the 20-hour rate and up to 210 W/cell at 15 minutes (1.67Vpc, 25°C),
it provides reliable ride-through and backup power for smaller UPS systems, datacenters, switchgear, and control panels
where rack space is at a premium.

Designed for a 10-year service life, the SWU210-12FR features a flame-arresting one-way vent, epoxy-sealed
terminals, and a flame-retardant UL94V-0 ABS case to enhance safety in high-density battery cabinets.
The maintenance-free, non-spillable AGM construction meets DOT/IATA requirements for non-hazardous transport,
while top-mounted M6 terminals simplify cabinet and rack installation. Certified to ISO 9001, ISO 14001,
and IEC 60896-21
and recognized by UL, this battery is ready for modern enterprise and industrial backup systems.

Key Features
  • 12V, 60Ah (20-hr) VRLA AGM battery optimized for high-temperature standby use.
  • 210 W/cell @ 15 min (1.67Vpc, 25°C) for dependable short-duration UPS support.
  • 10-year design life with low monthly self-discharge (~3% at 25°C).
  • Flame-retardant UL94V-0 ABS case, flame-arresting one-way vent, and epoxy-sealed terminals.
  • Maintenance-free, non-spillable AGM design; DOT/IATA compliant for transportation.
  • Top M6 terminals (recommended torque 4.9 Nm / 43 in-lb) for secure, repeatable connections.
  • Wide operating temperature range: discharge from −20°C to 60°C (−4°F to 140°F); operating range −40°C to 65°C (−40°F to 149°F).
  • Certified to ISO 9001, ISO 14001, IEC 60896-21; UL recognized component (U1989); TAA compliant and DRC conflict-free.
Quick Specs
Parameter Value
Model SWU210-12FR
Nominal Voltage 12 V
Capacity 60.0 Ah (20-hr rate @ 1.75Vpc, 25°C)
15-min Power 210 W/cell @ 1.67Vpc, 25°C
Short-Circuit Current 1240 A
Maximum Charge Current 13.6 A
Internal Resistance 5.0 mΩ
Dimensions (L × W × H over terminal) 226.0 × 135.0 × 210.0 mm (8.90″ × 5.31″ × 8.27″)
Case Height 207.0 mm (8.15″)
Weight 18.4 kg (40.57 lb)
Float Charge Voltage @ 25°C 2.275 ±1% V/cell (−3mV/°C per cell)
Design Life 10 years (standby)
Typical Applications UPS, datacenter, switchgear & control, energy storage and backup power