| Voltage | AH/kVA | Length | Width | Height | Weight |
|---|---|---|---|---|---|
| 300 kVA | 480 VAC | 31.5″ | 65.1″ | 73.5″ | 4,177 lb |
| Voltage | 300Â kVA |
| Amp/H | 480Â VAC |
| Length | 31.5″ |
| Width | 65.1″ |
| Height | 73.5″ |
| Weight | 4,177Â lb |
The Powerware 9315-300 is a heavy-duty online UPS for large data centers and industrial loads.
Units are fully reconditioned, cosmetically refreshed, and tested in the USA for dependable, ready-to-deploy service.
| Category | Detail |
|---|---|
| Power & Topology | 300 kVA; double-conversion on-line; sine-wave output; Hot Sync™ parallel capable; rating options: 240 kW @ 0.8 PF or 270 kW @ 0.9 PF. |
| Input | 480 VAC 3-phase (3-wire + G); 57–63 Hz; voltage window 408–528 VAC. With input filter — nominal/max input current (480 V): 333/416 A (0.8 PF) or 405/450 A (0.9 PF). Without input filter — nominal/max input current (480 V): 384/480 A (0.8 PF) or 476/529 A (0.9 PF). Typical PF with filter ≈0.95; THDi ≤~7% with filter (family spec ≤10% with filter). |
| Output | 480 VAC 3-phase; voltage regulation ±1% (static); transient ≤5% at 100% step; VTHD <3% (linear) / <5% (100% non-linear). Nominal output current (480 V): 360 A; 10-minute max: 450 A. Frequency ±0.005–0.01 Hz free-running; sync range ±0.5 Hz; slew ≤1 Hz/s. |
| Bypass | Integrated static bypass; bypass window typically +5%/−8% of output setting; bypass nominal current (480 V): 360 A. |
| Short-Circuit / AIC | Coordinate per site one-line and protective device study (installation-dependent). |
| Battery System | External VRLA plant; DC link 480Â Vdc nominal / 540Â Vdc float / 401Â Vdc end-of-discharge. Max battery EOD current (480Â V): 600Â AÂ dc (0.8Â PF) or 675Â AÂ dc (0.9Â PF). |
| Controls & Comm | Front monitor & control panels; X-Slot cards (ConnectUPS-X web/SNMP, Modbus), serial ports; building alarm inputs; EPO/REPO. |
| Physical | 73.5″ H Ă— 65.1″ W × ~31.5″ D Installed weight (UPS cabinet): 4,177 lb (1,895 kg). |
| Environment | Operating 0–40 °C; ≤95% RH non-condensing; ≤1500 m (5,000 ft) without derating; acoustic noise <65 dBA @ 1 m. |
| Accessory | Model | Notes |
|---|---|---|
| Maintenance Bypass Cabinet | MBB (site-specific) | Wrap-around service bypass for maintenance/testing |
| Input/Output Transformer Cabinet | Factory options | Voltage adaptation & isolation (e.g., 480↔208 V) |
| Power Distribution Module | PDM cabinet | 42-pole panelboard sidecar for 208Â V distributions |
| Battery Plant | Line-up-and-match | External VRLA cabinets sized to runtime; RBB/DC disconnects |