Powerware – 9315-300 – UPS – Refurbished

Manufacturer

OEM Part Number

9315-300

GPS Part Number

9315-300

Categories

Price:

$24,950.00

Specifications
View Spec Sheet
Voltage AH/kVA Length Width Height Weight
300 kVA 480 VAC 31.5″ 65.1″ 73.5″ 4,177 lb
Voltage 300 kVA
Amp/H 480 VAC
Length 31.5″
Width 65.1″
Height 73.5″
Weight 4,177 lb

Refurbished UPS — Eaton Powerware (9315-300)

480 V three-phase (60 Hz) •
True double-conversion (VFI) •
0.8 PF standard (0.9 PF option) • Tower cabinet

The Powerware 9315-300 is a heavy-duty online UPS for large data centers and industrial loads.
Units are fully reconditioned, cosmetically refreshed, and tested in the USA for dependable, ready-to-deploy service.

What you get
  • Thorough refurbishment — inspection, OEM-spec wear-part replacement, repaint, final QA
  • Comprehensive testing — burn-in, functional verification, alarm clear
  • Network-ready — X-Slot communications (SNMP/web, Modbus, serial); local monitor panel
  • Configured to order — common 480/480 V line-ups; transformer options for other voltages
  • U.S. warranty & support from Gruber Power Services

Technical Specifications — 9315-300
Category Detail
Power & Topology 300 kVA; double-conversion on-line; sine-wave output; Hot Sync™ parallel capable; rating options: 240 kW @ 0.8 PF or 270 kW @ 0.9 PF.
Input 480 VAC 3-phase (3-wire + G); 57–63 Hz; voltage window 408–528 VAC.
With input filter — nominal/max input current (480 V): 333/416 A (0.8 PF) or 405/450 A (0.9 PF).
Without input filter — nominal/max input current (480 V): 384/480 A (0.8 PF) or 476/529 A (0.9 PF).
Typical PF with filter ≈0.95; THDi ≤~7% with filter (family spec ≤10% with filter).
Output 480 VAC 3-phase; voltage regulation ±1% (static); transient ≤5% at 100% step; VTHD <3% (linear) / <5% (100% non-linear).
Nominal output current (480 V): 360 A; 10-minute max: 450 A.
Frequency ±0.005–0.01 Hz free-running; sync range ±0.5 Hz; slew ≤1 Hz/s.
Bypass Integrated static bypass; bypass window typically +5%/−8% of output setting; bypass nominal current (480 V): 360 A.
Short-Circuit / AIC Coordinate per site one-line and protective device study (installation-dependent).
Battery System External VRLA plant; DC link 480 Vdc nominal / 540 Vdc float / 401 Vdc end-of-discharge.
Max battery EOD current (480 V): 600 A dc (0.8 PF) or 675 A dc (0.9 PF).
Controls & Comm Front monitor & control panels; X-Slot cards (ConnectUPS-X web/SNMP, Modbus), serial ports; building alarm inputs; EPO/REPO.
Physical 73.5″ H Ă— 65.1″ W × ~31.5″ D  Installed weight (UPS cabinet): 4,177 lb (1,895 kg).
Environment Operating 0–40 °C; ≤95% RH non-condensing; ≤1500 m (5,000 ft) without derating; acoustic noise <65 dBA @ 1 m.

Battery Cabinets & Options
Accessory Model Notes
Maintenance Bypass Cabinet MBB (site-specific) Wrap-around service bypass for maintenance/testing
Input/Output Transformer Cabinet Factory options Voltage adaptation & isolation (e.g., 480↔208 V)
Power Distribution Module PDM cabinet 42-pole panelboard sidecar for 208 V distributions
Battery Plant Line-up-and-match External VRLA cabinets sized to runtime; RBB/DC disconnects

Notes
  • Values shown are the 9315-300 model rows for 480 V; 208/600 V variants exist with different currents and line-ups.
  • Width reduction via removable wireway is for ingress; verify clearances and conduit landing with the installation drawings.

Why buy from Gruber
  • Professionally refurbished — Restored in our electronics engineering lab.
  • Ready to install — Service-friendly access; proven reliability.
  • Guaranteed quality — Backed by our no-hassle 1-year full replacement warranty.