$920.00
Voltage | AH/kVA | Length | Width | Height | Weight |
---|---|---|---|---|---|
240/208 | 3 kVA | 16 | 15 | 8 | 21 lbs |
Voltage | 240/208 |
Amp/H | 3 kVA |
Length | 16 |
Width | 15 |
Height | 8 |
Weight | 21 lbs |
This Split-Phase Power Module, Eaton PN โ ASY-0673, is available in either completely refurbished or tested versions.
This split-phase Power Module, Eaton PN โ ASY-0673, has been expertly refurbished with a complete capacitor replacement and a refresh/replacement of all critical wear items. Each unit is serviced in our professional electronics lab by experienced engineers to ensure maximum reliability and long-term performance.
As a four-decade industry veteran, Gruber Power pioneered the refurbishment of critical power equipment modules like this. Our meticulous rebuild process includes full load bank testing in our UPS Depot Operations, simulating worst-case conditions to validate proper operation under real-world loads.
Our Critical Power Module rebuild process resets the module to factory specifications and optimal performance, extends service life, and reduces the risk of unplanned downtimeโat a fraction of the cost of a brand-new replacement.
Backed by our full 1-Year Warranty, this refreshed module delivers dependable performance and peace of mind for mission-critical Eaton PowerWare 9170+ systems (3โ18 kVA) requiring split-phase output.
Both the tested and refurbished options are fully load-bank tested for worst-case peak demand operation and serviced in our professional electronics lab by experienced engineers to ensure top reliability and performance.
Option | Description | Warranty |
---|---|---|
Tested | Operationally verified power module. Passed load bank testing and QC inspection without component-level refurbishment. |
90‑DAY
|
Refurbished | Fully rebuilt with new capacitors, fans, and other wear items. Reconditioned to like-new performance and appearance. |
1‑YEAR
|
Module | Front Label | Output Type | Typical Nominal Output(s) | Typical Regions / Use |
---|---|---|---|---|
ASY-0567 | Brown/Gold | Split-phase (dual leg) | 100/100 V (200 V), 110/110 V (220 V), 120/120 V (240 V) | North America, South America, Japan |
ASY-0673 | Brown | Split-phase (dual leg) | 100/100 V (200 V), 110/110 V (220 V), 120/120 V (240 V) | North America, South America, Japan |
ASY-0674 | Black | Single-phase (universal) | 200, 208, 220, 230, 240 V | Europe, Middle East, Asia, Africa |
Note: ASY-0673 and ASY-0674 are not interchangeable within the same 9170+ UPS chassis. Mixing module types can cause configuration and operational incompatibilities.