Shop Products

Our Companies

Call Now For Support
1-800-658-5883

APC – ACRD601 – InRow RD – 600mm Air Cooled – 460-480v – 60Hz – New

Manufacturer

OEM Part Number

ACRD601

GPS Part Number

67-APC-ACRD601

Categories

Price:

$32,992.38

Specifications
Voltage WPC AH/kVA Length Width Height Weight
460/480 V N/A N/A 42.1" 23.6" 78.4" 862 lb
Voltage 460/480 V
WPC N/A
Amp/H N/A
Length 42.1"
Width 23.6"
Height 78.4"
Weight 862 lb

APC InRow RD Air-Cooled Cooling Unit — ACRD601

Width: 600 mm  •  Input: 460–480 V, 60 Hz  •  Cooling: Air-Cooled DX  •  Condition: Factory New

The APC ACRD601 InRow RD Air-Cooled Cooling Unit is a factory-new Schneider Electric Uniflair system for precision cooling in high-density IT environments. Its 600 mm cabinet installs directly in the rack row, placing conditioned airflow close to the equipment. The direct-expansion (DX) system pairs with a compatible APC outdoor condenser for heat rejection.

Features
  • Close-Coupled Precision Cooling — the InRow RD Air-Cooled Cooling Unit delivers conditioned air at the rack row to help reduce hot and cold air mixing.
  • Variable-Speed EC Fans — adjust airflow as cooling demand changes.
  • Local Controls & Monitoring — includes a local display and alarms, with APC monitoring and building management integration options.
  • Matched Outdoor Heat Rejection — designed for use with a compatible APC outdoor condenser.
  • Factory-New OEM Equipment — supplied in APC/Schneider Electric packaging with manufacturer warranty and support.

Technical Specifications Detail
Manufacturer APC / Schneider Electric
Model ACRD601
Product Type Uniflair InRow RD Air-Cooled Cooling Unit for indoor installation
Condition Factory new
Cooling Capacity See the ACRD601 datasheet for nominal sensible capacity at the specified operating conditions.
Power Input 460–480 V, 60 Hz. See the unit nameplate for minimum circuit ampacity and maximum overcurrent protection.
Cooling Method Air-cooled direct expansion (DX) with a compatible outdoor condenser
Refrigerant R-410A. See the unit documentation for charge requirements.
Airflow Variable-speed EC fans with front-to-back airflow
Controls & Monitoring Uniflair controller with local display, alarms, APC monitoring compatibility, and building management integration options
Cabinet 600 mm wide (approximately 23.6 in.), nominal 42U height. See the mechanical drawing for exact dimensions and weight.
Installation Environment Indoor IT spaces. See the datasheet for temperature, humidity, and altitude limits.

Options & Accessories
Accessory Detail
Outdoor Condenser Select a compatible APC ACCD / ACCU series condenser for the required capacity and site voltage.
Leak Detection Optional Uniflair leak detection kit with alarm integration.

Installation Notes

The InRow RD Air-Cooled Cooling Unit requires a compatible outdoor condenser and refrigerant piping. Plan for condensate drainage and confirm condenser selection, piping requirements, and electrical ratings against the unit documentation. Professional installation and commissioning are recommended.

Why Buy from Gruber Power Services
  • Authorized APC Distributor — genuine, factory-new APC/Schneider Electric equipment.
  • Equipment Selection Assistance — help with cooling unit selection, condenser matching, and piping layout.
  • Manufacturer Warranty Support — OEM warranty coverage and support through Gruber.