APC – Galaxy VS – 75000 – 75 kVA – Three Phase Online UPS

Manufacturer

OEM Part Number

APC-GVSUPS75KFS

GPS Part Number

67-APC-GVSUPS75KFS

Price:

Call for Price

Specifications
View Spec Sheet
Voltage AH/kVA Length Width Height Weight
208VAC 75 Kva 34" 21" 59" 706ย lb
Voltage 208VAC
Amp/H 75 Kva
Length 34"
Width 21"
Height 59"
Weight 706ย lb
Galaxy VS UPS โ€” 75 kW / 75 kVA, 208 V 3-Phase (External Battery System Required)

Highly efficient, easy-to-deploy 75 kW, 208 V three-phase UPS delivering best-in-class power protection and low total cost of ownership for edge, small and medium data centers, and commercial & industrial critical infrastructure. Designed for external battery cabinets, allowing full runtime customization based on site requirements. Includes 5ร—8 start-up service for professional commissioning.

Why these fail
  • Improper battery sizing โ€” external banks are mismatched to discharge current or runtime goals.
  • High harmonic loads โ€” excessive distortion stresses rectifier components and increases heat.
  • Underestimated fault levels โ€” installations exceed equipment short-circuit withstand capability.
  • Commissioning shortcuts โ€” sync, bypass, and overload parameters not validated under real load.
Our solution
  • High efficiency operation โ€” optimized from 177โ€ฆ239 V (208 V nominal range).
  • Low input distortion โ€” < 3% THD at full load for cleaner upstream power.
  • Built-in static bypass โ€” seamless transfer during overload or internal fault events.
  • Flexible runtime design โ€” supports external VRLA or lithium battery cabinets (site-configured).
  • 5ร—8 start-up included โ€” factory-authorized commissioning and configuration validation.
Category Detail
Rated Output 75 kW / 75 kVA
Input Voltage 200 / 208 / 220 V AC, 3-phase
Output Voltage 200 / 208 / 220 V AC, 3-phase
Input Current (Max/Phase) 269 A
Short-Circuit Withstand (Icw) 65 kA
Input THD Less than 3% at full load
Load Power Factor 0.7 leading to 0.7 lagging without derating
Frequency Input 40โ€“70 Hz โ€ข Output 50/60 Hz (sync to mains)
Bypass Built-in static bypass
Overload Capability 10 min @ 125% โ€ข 60 sec @ 150%
Voltage Regulation ยฑ1% after 50 ms
Crest Factor 2.5
Battery Configuration External battery cabinets required (VRLA or lithium, site configured)
Service & coverage

5ร—8 start-up service ensures proper commissioning, parameter setup, and operational validation. External battery runtime is determined by cabinet configuration and site load profile.

๐Ÿ’ก
Design tip: Confirm DC bus voltage compatibility and maximum discharge current when selecting external battery cabinets for 75 kW load support.
๐Ÿ› ๏ธ
Tech support: Need help sizing external battery cabinets or confirming 200/208/220 V site compatibility? Email gps@gruber.com.
Gruber Power Services