Shop Products

Our Companies

Call Now For Support
1-800-658-5883

APC – Galaxy VL – 500000- 500 kVa – Three Phase Online UPS

Manufacturer

OEM Part Number

APC-GVL

GPS Part Number

67-APC-GVL

Price:

Call for Price

Specifications
View Spec Sheet
Voltage AH/kVA Length Width Height Weight
208VAC 75 Kva 34" 21" 59" 706 lb
Voltage 208VAC
Amp/H 75 Kva
Length 34"
Width 21"
Height 59"
Weight 706 lb
Galaxy VL UPS — 200 kW scalable to 500 kW (400/480 V, 3-Phase) •  5×8 Start-Up Included
Lead time: Special order — call for quoted lead times

Highly efficient, modular, high-density 200 kW three-phase UPS platform designed for medium, large, and edge data centers, plus critical infrastructure in commercial and industrial environments. Built to scale as your load grows — start at 200 kW and expand up to 500 kW without forklift upgrades. Includes 5×8 start-up service.

Why these fail
  • Growth outpaces design — single-frame UPS sized for today becomes a bottleneck tomorrow.
  • Battery strategy mismatch — chemistry and cabinet selection don’t align with runtime, footprint, or lifecycle goals.
  • Non-linear loads — harmonic-rich environments add heat and reduce efficiency without proper UPS sizing.
  • Commissioning gaps — settings and protection modes not validated under real facility conditions.
Our solution
  • Modular scalability — deploy 200 kW now and scale up to 500 kW as load increases.
  • Wide voltage support — supports common 380/400/415/440/480 V three-phase environments.
  • Low output distortion — output THD < 1% (linear) / < 5% (non-linear) for cleaner downstream power.
  • Battery flexibility — compatible with external Li-ion, VRLA, or Ni-Cd systems (sold separately).
  • 5×8 start-up included — professional commissioning and configuration validation.
Category Detail
Rated Output 200 kW / 200 kVA (scalable platform)
Max Scalable Capacity Up to 500 kW / 500 kVA
Input Voltage 380 / 400 / 415 / 440 / 480 V AC, 3-phase
Output Voltage 380 / 400 / 415 / 440 / 480 V AC, 3-phase (Other: 400 V, 480 V)
Frequency Input 40–70 Hz
Short-Circuit Withstand (Icw) 65 kA
Input THD Less than 5% at full load
Load Power Factor 0.5 leading to 0.5 lagging without derating
Output THD < 1% linear load • < 5% non-linear load
Overload Capability 10 min @ 125% • 60 sec @ 150%
Crest Factor 3
Battery System External batteries (sold separately): Li-ion, VRLA, or Ni-Cd
End-of-discharge battery voltage: 384 V
User Interface Touch Screen LCD
Service & coverage

Included 5×8 start-up service supports proper commissioning, configuration validation, and operational verification. Battery runtime is determined by external cabinet configuration, battery chemistry, and site load profile.

💡
Design tip: If you’re planning a future expansion (200 → 500 kW), size upstream feeders, bypass, and battery cabinets for the end state to avoid rework.
🛠️
Tech support: Need help quoting lead time, selecting the right voltage (400 vs 480), or building a battery runtime plan (Li-ion / VRLA / Ni-Cd)? Email gps@gruber.com.
Gruber Power Services