Liebert – NXB – 30 KVA – UPS – Refurbished

Manufacturer

OEM Part Number

38SA030C0CHR

GPS Part Number

38SA030C0CHR

Price:

$8,146.23

Specifications
View Spec Sheet
Voltage AH/kVA Length Width Height Weight
30 kVA / 24 kW 120/208 VAC 32.5″ 24.0″ 63.0″ 550 lb
Voltage 30 kVA / 24 kW
Amp/H 120/208 VAC
Length 32.5″
Width 24.0″
Height 63.0″
Weight 550 lb

Refurbished UPS — Vertiv Liebert NXb 30 kVA
(NXB-30KVA)

120/208 V 3-phase (4-wire + G) •
True double-conversion (VFI) •
UL 1778 • Tower cabinet

The Liebert NXb 30 kVA is a compact three-phase on-line UPS from the 10–30 kVA family, delivering tight voltage regulation,
low input distortion, and robust overload handling for server rooms and small data centers. Each unit is reconditioned, cosmetically
refreshed, and tested in the USA for dependable, ready-to-deploy service.

What you get
  • Thorough refurbishment — inspection, OEM-spec wear-part replacement, repaint, final QA
  • Comprehensive testing — burn-in, functional verification, alarms cleared
  • Network-ready — graphical LCD/HMI; IntelliSlot options (SNMP/Modbus/relay)
  • Configured to order — 120/208 V single- or dual-mains with integrated static bypass (by build)
  • U.S. warranty & support from Gruber Power Services

Technical Specifications — NXb 30 kVA
Category Detail
Power & Topology 30 kVA / 24 kW; on-line, true double-conversion; sine-wave output
Input 120/208 VAC, 3-phase, 4-wire + G; voltage range +10%/−20%; 57–63 Hz;
reflected input THDi ≤4% (full load); input PF ≈0.99 (full load); current walk-in 20 s; current limit 125% FL;
nominal / max input current 83 / 104 A; recommended input OCPD 125 A.
Output 120/208 VAC, 3-phase (3- or 4-wire + G); voltage adjust ±5%; regulation 1% (balanced) / 2% (100% unbalanced);
dynamic ±5% for 100% step with ½-cycle recovery; VTHD ≤1% (linear), <4% (100% non-linear); frequency reg. ±0.05% (single);
nominal output current 84 A; recommended output OCPD 125 A.
Bypass Integrated static bypass; external service bypass via matching distribution cabinet or site MBB (by configuration).
Short-Circuit / AIC Site-specific; coordinate with upstream/downstream protective devices and one-line study.
Battery System Nominal DC bus 288 Vdc; maximum battery end-of-discharge current ≈110 A dc (30 kVA row);
internal battery option (HR pack) ~9 min at 30 kVA; external VRLA battery cabinets for extended runtime.
Controls & Comm Graphical LCD/HMI with metering, alarms, event log; IntelliSlot network cards (SNMP/web), RS-485/Modbus, and dry-contact/relay options; EPO/REPO input.
Physical 24.0″ W × 32.5″ D × 63.0″ H (610 × 826 × 1600 mm); weight ≈ 550 lb (250 kg);
heat dissipation ≈ 8,300 BTU/h; cooling air ≈ 834 CFM.
Environment Operating 32–104 °F (0–40 °C); ≤95% RH non-condensing; altitude to ~3,300 ft (1,000 m) without derating; acoustics <54 dBA @1 m.

Battery Cabinets & Options
Accessory Model Notes
External Battery Cabinet EBC (various) Extends runtime; sized to desired minutes at load
SlimLine Power Distribution Cabinet SL-PDC (42-pole) Bolt-on sidecar for NX 10–30 kVA with panelboard distribution
IntelliSlot Network Card IS-UNITY-DP / Web Card SNMP/Web, BACnet/Modbus integration; remote monitoring

Notes
  • Electrical and accessory options (single- vs. dual-mains, sidecar distribution) vary by build; confirm on the project cut-sheet.
  • Internal battery runtimes and weights are per OEM HR/FR pack tables; external cabinets recommended for longer runtimes.