Manufacturer
OEM Part Number
GPS Part Number
Categories
Tags
$18,445.00
Voltage | AH/kVA | Length | Width | Height | Weight |
---|---|---|---|---|---|
80ย kVA / 64ย kW | 208 or 480ย VAC | 32.5โณ | 39.4โณ | 71โณ | 2,300โ2,700ย lb |
Voltage | 80ย kVA / 64ย kW |
Amp/H | 208 or 480ย VAC |
Length | 32.5โณ |
Width | 39.4โณ |
Height | 71โณ |
Weight | 2,300โ2,700ย lb |
The Liebert Npower 80ย kVA is a rugged, legacy three-phase on-line UPS known for excellent dynamic response and low output distortion.
Our refurbished units are fully reconditioned, cosmetically refreshed, and tested in the USA for dependable, ready-to-deploy service.
Category | Detail |
---|---|
Power & Topology | 80ย kVA / 64ย kW; true double-conversion on-line; sine-wave output; outstanding dynamic response |
Input | 208 or 480ย VAC, 3-phase (3- or 4-wireย +ย G); voltage range +10%/โ15% (no battery discharge at โ20%); 60ย Hzย ยฑ5%; current walk-in โ20ย s; reflected input THD โค10% with input filter; power factor โฅ0.95 at full load with input filter |
Output | 208 or 480ย VAC, 3-phase, 4-wireย +ย G; voltage regulation ยฑ0.5% (balanced), ยฑ1.0% (100% unbalanced); dynamic regulation ยฑ2.5% at 100% step (recovers to ยฑ1% within 1 cycle); VTHD โ1% (linear), <2.5% at 100% non-linear; frequency regulation ยฑ0.1%; load PF 1.0 to 0.7 lagging without derating; overload 125% for 10ย min / 150% for 1ย min |
Bypass | Static bypass; external wrap-around Maintenance Bypass Cabinet (MBB) available |
Short-Circuit / AIC | Coordinate per site one-line and protective device study (rating varies by installation) |
Battery System | External VRLA battery cabinets; nominal DC bus 480ย V; runtime scales with cabinet count and AH; remote battery breaker (RBB) / multiple battery breaker options available |
Controls & Comm | Menu-driven LCD HMI; optional network/SNMP, Modbus/RS-485, and relay I/O options; dial-out/dial-in remote alerts (as equipped) |
Physical | Approx. 39.4โณย W ร 32.5โณย D ร 71โณย H (65โ80ย kVA frame); typical weight ~2,300โ2,700ย lb (by configuration) |
Environment | Operating 0โ40ย ยฐC; 0โ95% RH non-condensing; altitude to 2000ย m without derating; acoustics <65ย dBA; heat dissipation ~18,000โ22,000ย BTU/h (configuration dependent) |
Accessory | Model | Notes |
---|---|---|
Maintenance Bypass Cabinet | MBB / site-specific | Wrap-around service bypass for maintenance |
Slim-Line Distribution Cabinet | SLDC | Compact downstream distribution cabinet |
Remote Battery Breaker | RBB / MBB variants | Remote battery isolation and multi-cabinet support |
Battery Plant | Site-engineered | VRLA cabinets sized to required runtime (480ย Vdc bus) |