Products

Call Now For Support
1-800-658-5883

APC – SYA16K16P – Symmetra LX – UPS – Refurbished

Manufacturer

OEM Part Number

SYA16K16PXR

GPS Part Number

59-APC-SYA16K16PXR

Price:

$13,735.23

Specifications
View Spec Sheet
Voltage AH/kVA Length Width Height Weight
16 kVA / 12.8 kW 208 VAC 28.58″ 19.02″ 36.89″ 678 lb
Voltage 16 kVA / 12.8 kW
Amp/H 208 VAC
Length 28.58″
Width 19.02″
Height 36.89″
Weight 678 lb

Refurbished UPS — APC/Schneider Electric Symmetra LX 16 kVA
(SYA16K16P)

208/240 V input (4-wire, 2PH+N+G) •
Configurable 120/208 or 120/240 V output •
True double-conversion (VFI) • Modular N+1 tower

Symmetra LX provides scalable, modular on-line protection in 4 kVA increments. This 16 kVA system
is fully reconditioned, cosmetically refreshed, and tested in the USA for reliable, ready-to-deploy service.

What you get
  • Thorough refurbishment — inspection, wear-part replacement to OEM spec, repaint, final QA
  • Comprehensive testing — burn-in, functional verification, alarms cleared
  • Network-ready — LCD HMI; pre-installed Network Management Card 2; SmartSlot expansion
  • Configured to order — common input/output and bypass arrangements
  • U.S. warranty & support from Gruber Power Services

Technical Specifications — SYA16K16P
Category Detail
Power & Topology 16 kVA / 12.8 kW; true double-conversion on-line; modular N+1; 4 kVA power increments
Input 208 VAC nominal (240 VAC supported); hard-wire 4-wire (2PH+N+G); 45–65 Hz auto-sensing; input PF ≈0.98; THDi <7% at full load
Output Configurable 120/208 or 120/240 VAC, 4-wire (2PH+N+G); 47–63 Hz sync to mains; ±0.1% free-running; <5% THD; crest factor up to 5:1; max output current 75 A
Bypass Internal bypass (automatic & manual)
Short-Circuit / AIC Site-specific; coordinate with upstream/downstream protection and one-line
Battery System VRLA lead-acid; included battery modules: 4; typical recharge ≈3 h; extend runtime with external SYAXR9B9 battery cabinets
Controls & Comm Multi-function LCD console; Network Management Card 2 pre-installed; 1 SmartSlot free; EPO
Physical 36.89″H Ă— 19.02″W Ă— 28.58″D (93.7 × 48.3 × 72.6 cm); ~678 lb (307.7 kg); heat dissipation ≈4,995 BTU/h; acoustic noise ≈62 dBA
Environment Operating 0–40 °C; 0–95% RH (non-condensing); altitude 0–10,000 ft

Battery Cabinets & Options
Accessory Model Notes
4 kVA Power Module SYPM4KP Four installed for 16 kVA; add one for N+1 redundancy
Battery Module SYBT5 Four installed; hot-swappable VRLA
Intelligence Module SYMIM5 Dual intelligence modules for control redundancy (as equipped)
Extended-Run Battery Cabinet SYAXR9B9 Scales runtime; multiple cabinets supported
External Maintenance Bypass MBB (site-specific) Wrap-around service bypass option

Notes
  • Configurable outputs support 120/208 or 120/240 V; verify distribution/backplate needs.
  • Electrical limits and module counts can vary by build; confirm on the project cut-sheet.
  • Batteries/cabinets sold separately unless specified; runtime depends on battery configuration.

Why buy from Gruber
  • Professionally refurbished — Restored in our electronics engineering lab.
  • Ready to install — Plug-and-play functionality with hot-swap modules.
  • Guaranteed quality — Backed by our no-hassle 1-year full replacement warranty.
Gruber Power Services