Voltage AH/kVA Length Width Height Weight
160 kVA / 144 kW 208 V 31.6" 35.6" 73.7" 1220 lb -1280 lb
Voltage 160 kVA / 144 kW
Amp/H 208 V
Length 31.6"
Width 35.6"
Height 73.7"
Weight 1220 lb -1280 lb

Refurbished UPS โ€” Eaton/Powerware (PW9390-160)

208/220 or 480 V, 3-phase โ€ข
Transformer-free double-conversion (VFI) โ€ข
0.9 PF (144 kW) โ€ข Integrated static bypass

Exact OEM specifications for the Powerware 9390 160 kVA, formatted in our standard template. Units are fully reconditioned,
cosmetically refreshed, and tested in the USA for dependable, ready-to-deploy service.

What you get
  • Thorough refurbishment โ€” inspection, OEM-spec wear-part replacement, repaint, final QA
  • Comprehensive testing โ€” burn-in, functional verification, alarms cleared
  • Network-ready โ€” front LCD/HMI; dual X-Slot bays (SNMP/web, Modbus/RS-485, relay)
  • Configured to order โ€” 208/220 or 480 V line-ups with integrated bypass
  • U.S. warranty & support from Gruber Power Services

Technical Specifications โ€” PW9390-160
Category Detail
Power & Topology 160 kVA / 144 kW; transformer-free true double-conversion (VFI) with IGBT rectifier and PWM inverter; Hot Sync parallel-capable; variable DC bus 384/432/480 V (192โ€“240 cells).
Input Operating window (nominal +10% / โˆ’15%): 208 V = 177โ€“229 V; 220 V = 187โ€“242 V; 480 V = 408โ€“528 V. Frequency range ยฑ5 Hz of nominal (50/60 Hz).
Input PF โ‰ฅ 0.99 (full load); input current distortion โ‰ค 5% THDi (full load).
Rectifier input current (full load + recharge): 480 A @ 208/220 V; 210 A @ 480 V.
Output Regulation (10โ€“100% load) ยฑ1%; adjustable nominal (ยฑ3%): 208 V = 202โ€“214 V; 220 V = 214โ€“226 V; 480 V = 466โ€“494 V.
Voltage distortion โ‰ค 1.5% THD (linear) / โ‰ค 5% THD (non-linear); transient ยฑ5% for 100% step/removal.
Frequency ยฑ0.01 Hz free-running; sync to bypass within ยฑ0.5 Hz; slew โ‰ค 1 Hz/s.
Full-load output current: 444/420 A @ 208/220 V; 193 A @ 480 V.
Bypass Integrated static bypass; permissible window +5% / โˆ’8% of output setting; sync bandwidth ยฑ0.5 Hz. Bypass full-load current: 444/420 A @ 208/220 V; 193 A @ 480 V.
Short-Circuit / AIC Coordinate breaker/withstand ratings per site one-line and configured lineup.
Battery System External Integrated Battery Cabinets (IBC-S / IBC-L); variable DC bus 384/432/480 V. DC current at 2.0 V/cell (end-of-discharge): 403 A dc.
Controls & Comm Front LCD/HMI with metering and event log; dual X-Slot bays (web/SNMP, Modbus/RS-485, serial); remote alarm I/O; REPO.
Physical 100โ€“160 kVA frame (UPS only): 73.7″ H ร— 35.6″ W ร— 31.6″ D (1873 ร— 904 ร— 804 mm).
Installed weight: 553 kg (1220 lb). Shipping weight: 581 kg (1280 lb). Point loading: 6 points @ 92 kg (204 lb) each.
Required clearances: front 36 in (914 mm); top 18 in (457 mm).
Environment Operating 0โ€“40 ยฐC (25 ยฐC recommended); altitude โ‰ค 1500 m at 40 ยฐC without derating; RH 5โ€“95% non-condensing; acoustics ~65 dB @ 1 m.
Heat rejection (full load): 47.3 kBTU/h (208/220 V units) or 43.8 kBTU/h (380/400/415/480 V units). Typical exhaust air ~2000 cfm.

Battery Cabinets & Options
Accessory Model Notes
Integrated Battery Cabinet IBC-S / IBC-L External runtime cabinets; variable 384โ€“480 Vdc bus.
Integrated Accessory Cabinet IAC-B / IAC-T / IAC-D Wrap-around maintenance bypass / tie options (matching sidecar).
Integrated Distribution Cabinet IDC (100โ€“160 kVA) Panelboard / subfeed distribution matched to 9390 line-ups.

Notes
  • All electrical and mechanical values are the OEM single-module specifications for 9390-160 (208/220 and 480 V variants).

Why buy from Gruber
  • Professionally refurbished โ€” Restored in our electronics engineering lab.
  • Ready to install โ€” Line-up-and-match IBC / IAC / IDC options available.
  • Guaranteed quality โ€” Backed by our no-hassle 1-year full replacement warranty.
Gruber Power Services