| 225 kVA / 202.5 kW | 480 VAC | 33.66″ | 47.83″ | 74.80″ | 2640 lb |
| Voltage | 225Â kVA / 202.5Â kW |
| Amp/H | 480Â VAC |
| Length | 33.66″ |
| Width | 47.83″ |
| Height | 74.80″ |
| Weight | 2640Â lb |
The MGE Galaxy PW 225Â kVA is a robust three-phase on-line UPS for medium data centers and industrial facilities.
Our refurbished units are fully reconditioned, cosmetically refreshed, and tested in the USA for reliable,
ready-to-deploy service.
| Category | Detail |
|---|---|
| Power & Topology | 225 kVA / 202.5 kW; true double-conversion on-line; efficiency ≈93% at mid-load |
| Input | 480 VAC, 3-phase, 3-wire + G; 60 Hz ±10%; THDi <7.5% at full load; input PF correction up to 0.9 at full load; configurable input current limit (typ. 360 A); rectifier walk-in to reduce generator inrush |
| Output | 480/208/600 VAC selections (site build); static regulation ±1%; dynamic ±5% @ 100% step; THDU <1% (linear), <4% (non-linear); overload 125% for 10 min / 150% for 60 s; slew 2 Hz/s (selectable); 0.9 load PF rating |
| Bypass | Integrated static bypass; make-before-break maintenance bypass available in sidecar/panel |
| Short-Circuit / AIC | Up to 65Â kAIC available depending on cable-entry/MBP configuration (see OEM drawings) |
| Battery System | External VRLA cabinets; nominal DC bus 480 Vdc (float 545 Vdc; EOD 390 Vdc); battery current @ full load ≈380 A (max @ EOD ≈547 A); typical recharge ≈12 h; end-cell >1.65 V |
| Controls & Comm | Front LCD/HMI; SNMP/web (IntelliSlot/Unity), RS-485/Modbus, dry-contact relays; EPO/REPO |
| Physical | 74.80″ H Ă— 47.83″ W Ă— 33.66″ D (1900 Ă— 1215 Ă— 855 mm); weight ≈ 2640 lb (1200 kg); heat dissipation ≈ 48,046 BTU/h; acoustics ≈ 68 dBA @ 1 m |
| Environment | Operating 0–40 °C; ≤95% RH non-condensing; no derate to ~1000 m, then typical capacity derate: 1500–2000 m ≈79%, 2000–2300 m ≈75%, 2300–3000 m ≈69%, 3000–4000 m ≈61% |
| Accessory | Model | Notes |
|---|---|---|
| External Battery Cabinets | Line-up & match (various) | Runtime scales by cabinet count & cell selection (480Â Vdc plant) |
| Maintenance/Parallel Bypass | External MBP / Parallel Bypass Cabinet | Make-before-break service bypass; parallel capacity/redundancy options |
| Auxiliary / Transformer Cubicle | Factory option | Input/output isolation or voltage adaptation; distribution sidecar variants |
| Network / Interface Cards | SNMP/Web, RS-485/Modbus, Relay | Remote monitoring & alarms; integrates with DCIM/BMS |