Manufacturer
OEM Part Number
GPS Part Number
Categories
Tags
$25,971.29
| Voltage | WPC | AH/kVA | Length | Width | Height | Weight |
|---|---|---|---|---|---|---|
| 225 kVA / 202.5 kW | N/A | 480 VAC | 33.66″ | 47.83″ | 74.80″ | 2640 lb |
| Voltage | 225Â kVA / 202.5Â kW |
| WPC | N/A |
| Amp/H | 480Â VAC |
| Length | 33.66″ |
| Width | 47.83″ |
| Height | 74.80″ |
| Weight | 2640Â lb |
Protect critical operations with the MGE Galaxy PW 225 kVA UPS, a three-phase power protection system for data centers, industrial facilities, and demanding commercial applications. Its online double-conversion architecture conditions incoming power and supplies regulated, sine-wave output with fast response to changing loads.
Each refurbished system from Gruber Power Services is reconditioned, cosmetically restored, and tested in the USA. Our team helps match the UPS, battery capacity, bypass equipment, and available accessories to your facility’s electrical requirements.
| Category | Details |
|---|---|
| Power & Technology | 225 kVA / 202.5 kW at 0.9 output power factor; online double-conversion. Listed efficiency is approximately 93% at mid-load, depending on configuration and operating conditions. |
| Input | 480 VAC, three-phase, 3-wire plus ground; 60 Hz ±10%. Listed full-load input current distortion: <7.5% THDi; input power factor up to 0.9, depending on input equipment. Configurable input current limit, with a listed typical setting of 360 A. Rectifier walk-in supports gradual load pickup. |
| Output | Output voltage depends on the supplied UPS and transformer arrangement; listed configurations include 480, 208, or 600 VAC. Static voltage regulation: ±1%; dynamic response: ±5% for a 100% load step. Voltage distortion: <1% with linear loads and <4% with nonlinear loads. Overload capability: 125% for 10 minutes or 150% for 60 seconds. Selectable frequency slew rate, with a listed setting of 2 Hz/second. |
| Bypass | Integrated static bypass. Compatible external maintenance bypass equipment is available in sidecar or panel arrangements. |
| Fault Ratings & Protection | Fault ratings depend on the supplied equipment, cable-entry arrangement, and maintenance bypass configuration. Confirm the applicable equipment rating and protective-device requirements against OEM drawings and the site’s available fault current. |
| Battery System | External VRLA battery system. Nominal DC bus: 480 VDC; listed float voltage: 545 VDC; end-of-discharge voltage: 390 VDC. Listed full-load battery current: approximately 380 A, with maximum end-of-discharge current approximately 547 A. Recharge time depends on battery capacity, discharge depth, and charger settings. |
| Controls & Monitoring | Front LCD/operator interface. Compatible options may include SNMP/web monitoring, RS-485/Modbus, dry-contact relays, and emergency power off / remote emergency power off connections, depending on installed hardware. |
| Dimensions & Weight | Approximately 47.83 W × 33.66 D × 74.80 H inches (1,215 × 855 × 1,900 mm). Listed weight: approximately 2,640 lb (1,200 kg). Additional battery cabinets, transformers, and sidecars increase total installation dimensions and weight. |
| Heat Output & Acoustics | Listed heat dissipation: approximately 48,046 BTU/hour. Sound level: approximately 68 dBA at 1 meter. Confirm the applicable load and operating conditions for facility planning. |
| Operating Environment | Operating temperature: 32–104°F (0–40°C). Relative humidity: ≤95%, non-condensing. Altitude derating may apply above approximately 1,000 meters; confirm the manufacturer’s altitude and temperature limits for the supplied configuration. |
| Option | Details |
|---|---|
| External Battery Cabinets | Compatible battery cabinets and strings sized for the required load and backup runtime. Battery configuration must match the UPS DC requirements. |
| Maintenance Bypass | Compatible external maintenance bypass equipment provides a service bypass path around the UPS. |
| Parallel System Equipment | Parallel bypass and control equipment for compatible capacity or redundancy arrangements, subject to system engineering and availability. |
| Auxiliary / Transformer Cabinet | Compatible isolation transformers, voltage-adaptation equipment, and distribution sidecars for the selected installation. |
| Communication Interfaces | Compatible network, Modbus, and relay interfaces for remote monitoring and alarms, subject to installed hardware and availability. |
Get a professionally refurbished UPS backed by our electronics engineering lab, configuration assistance, and 1-year full replacement warranty.
Contact Gruber Power Services for current availability, pricing, and a configuration matched to your facility.