Products

Call Now For Support
1-800-658-5883

APC – AP7863 – Power Distribution Unit – Tested

Manufacturer

OEM Part Number

AP7863

GPS Part Number

56-APC-AP7863

Tags

Price:

$149.99

Specifications
View Spec Sheet
Voltage AH/kVA Length Width Height Weight
208/120 Volt 5.7 kW 70" 2.2" 1.73" 12 lbs
Voltage 208/120 Volt
Amp/H 5.7 kW
Length 70"
Width 2.2"
Height 1.73"
Weight 12 lbs

APC NetShelter โ€” Metered Rack PDU (AP7863)

SKU: PDU-APC-AP7863 ย |ย  Type: 0U vertical, metered power distribution unit for multi-voltage racks (120/208ย V, 3-phase). The AP7863 delivers up to 5.7ย kVA with a local digital meter for load visibility and a mixed-receptacle layout to power both 120ย V and 208ย V gear in the same cabinet.

  • Mixed outlets: 21 ร— NEMA 5-20R (T-slot; accepts 5-15P/5-20P) + 6 ร— NEMA L6-20R for 208ย V equipment.
  • Input: 208ย V 3-phase Wye, L21-20P locking plug, 3ย ft (0.9ย m) cord.
  • Metered visibility: Front digital ammeter displays real-time load (per PDU/phase) to help prevent overloads.
  • Zero-U vertical mount: Preserves rack U-space; includes toolless mounting hardware and brackets.
  • Data center ready: UL/cUL listed, FCC Classย A; 0โ€“45ย ยฐC operating, 0โ€“95% RH (non-condensing).

Technical Specifications โ€” AP7863
Parameter Detail
PDU Type Metered, Zero-U vertical (0U)
Input 208ย V 3-phase (Wye), NEMA L21-20P; cord length 3ย ft (0.9ย m)
Current Input current limit 20ย A; line rated current 16ย A
Output Voltage 120ย V and 208ย V
Outlets 21 ร— NEMA 5-20R ย |ย  6 ร— NEMA L6-20R (total 27)
Load Capacity 5,700ย VA (5.7ย kW)
Frequency 50/60ย Hz
Dimensions (H ร— W ร— D) 70.00 ร— 2.20 ร— 1.73ย in (1778 ร— 56 ร— 44ย mm)
Net Weight 12.02ย lb (5.45ย kg) ย |ย  Ship wt. ~19.49ย lb (8.84ย kg)
Included Hardware Toolless mounting kit, rack brackets, installation guide, user manual
Certifications ULย 60950-1, cUL, FCC Classย A, ICES-003
Environment Operating: 32โ€“113ย ยฐF (0โ€“45ย ยฐC), 0โ€“95% RH; Storage: โˆ’13โ€“149ย ยฐF (โˆ’25โ€“65ย ยฐC)
Notes & Replacement

The AP7863 is an earlier-generation Metered PDU that has been discontinued. APCโ€™s recommended current replacement is the
AP8863 (NetShelter Metered PDU, 2G), a 0U 20A 120/208ย V 3-phase model with 24 ร— 5-20R and 6 ร— L6-20R outlets for similar mixed-voltage deployments.

Why buy from Gruber
  • Professionally tested โ€” Load-tested with outlets verified across phases.
  • Exact fit hardware โ€” Includes the proper 0U vertical mounting solution for NetShelter-style racks.
  • Mixed-voltage flexibility โ€” Power 120ย V IT gear and 208ย V servers in the same rack with one PDU.

Tags: , , ,
Gruber Power Services