APC – Symmetra PX – 100000 – 100 kVa – Three Phase Online UPS

Manufacturer

OEM Part Number

APC-SYMMPX

GPS Part Number

67-APC-SYMMPX

Price:

Call for Price

Specifications
View Spec Sheet
Voltage AH/kVA Length Width Height Weight
208VAC 100 Kva 34" 21" 59" 706ย lb
Voltage 208VAC
Amp/H 100 Kva
Length 34"
Width 21"
Height 59"
Weight 706ย lb
Symmetra PX UPS โ€” 100 kW / 100 kVA, 208 V 3-Phase (Modular) โ€ข Start-Up Included
Lead time: Usually ships within 3 weeks

The Symmetra PX 100 kW is a modular, high-efficiency, double-conversion online 3-phase UPS designed for small to medium data centers and high-density zones. Its modular architecture supports simplified serviceability and predictable scaling up to 100 kW, delivering clean, regulated power with fast transfer performance and low output distortion.

Why these fail
  • Overloaded high-density rows โ€” growth pushes systems to 100% capacity with no headroom.
  • Poor harmonic environments โ€” non-linear loads cause heat and stress without low-THD capability.
  • Slow response to load steps โ€” voltage excursions create nuisance alarms and downstream resets.
  • Commissioning gaps โ€” bypass and sync settings not validated under real load conditions.
Symmetra PX advantages
  • Double-conversion online โ€” continuous clean sine-wave output for sensitive loads.
  • Fast transfer performance โ€” 2 ms typical transfer time.
  • Tight regulation โ€” ยฑ1% static and ยฑ5% at 100% load step response.
  • Low output distortion โ€” < 2% harmonic distortion for linear loads; controlled THD for non-linear loads.
  • Modular serviceability โ€” optimized for uptime and maintainability in critical spaces.
Category Detail
Rated Output 100,000 W / 100,000 VA (100 kW / 100 kVA)
Input Voltage 208 V AC, 3-phase (optimized efficiency 177โ€ฆ239 V)
Output Voltage 208 V AC, 3-phase
Topology Double Conversion Online
Input Current (Max/Phase) 332 A
Input THD Less than 5% at full load
Power Factor / Cos ฯ† Load PF 0.5 leading to 0.5 lagging โ€ข Cos ฯ† 0.99
Output THD < 2% (0โ€“100% linear load) โ€ข < 6% (full non-linear load)
Output Regulation ยฑ1% static โ€ข ยฑ5% at 100% load step
Transfer Time 2 ms typical
Bypass Built-in static bypass
Waveform Pure sine wave
Output Frequency Sync to mains: 57โ€ฆ63 Hz (60 Hz nominal) โ€ข
Free-run: 60 Hz ยฑ0.1% or 50 Hz ยฑ0.1%
Output Wiring Hard-wire 5-wire (3PH + N + G) for 1 zone
Efficiency 94.7% (battery operation)
Runtime Reference 5 min 12 s at 100 kW (specified load window 10โ€“100 kW)
Service & commissioning

Start-up service supports proper commissioning, configuration validation, and operational verification prior to handoff โ€” especially important in high-density zones where load steps and harmonic content can be significant.

๐Ÿ› ๏ธ
Tech support: Need help confirming your kW load profile, runtime targets, or breaker/bypass coordination at 208 V? Email gps@gruber.com.