APC – Galaxy VX – 500000- 500 kVa – Three Phase Online UPS

Manufacturer

OEM Part Number

APC-GVX

GPS Part Number

67-APC-GVX

Price:

Call for Price

Specifications
View Spec Sheet
Voltage AH/kVA Length Width Height Weight
208VAC 75 Kva 34" 21" 59" 706ย lb
Voltage 208VAC
Amp/H 75 Kva
Length 34"
Width 21"
Height 59"
Weight 706ย lb
Galaxy VX UPS โ€” 500 kVA / 500 kW, 480 V N+1 Redundant (3-Phase) ย โ€ขย  5ร—8 Start-Up Included
Lead time: Special order โ€” call for quoted lead times

The Galaxy VX 500 kVA N+1 is a highly efficient, modular three-phase UPS engineered for large data centers and mission-critical applications. Designed for redundant (N+1) architecture, it delivers performance, scalability, and maximized asset utilization. This EcoStruxureโ„ข Ready platform achieves up to 99% efficiency using patented ECOnversion technology. Includes 5ร—8 start-up service.

Why large UPS systems fail
  • Lack of redundancy โ€” single-module systems create single points of failure.
  • Inefficient operation โ€” legacy UPS platforms waste energy at partial load.
  • High fault exposure โ€” inadequate short-circuit withstand ratings.
  • Poor harmonic control โ€” excessive distortion impacts upstream infrastructure.
Galaxy VX advantages
  • True N+1 modular redundancy โ€” protects against module-level failures.
  • Up to 99% efficiency with ECOnversion technology.
  • High short-circuits withstand โ€” rated up to 100 kA.
  • Low distortion output โ€” clean sine wave for sensitive IT and industrial loads.
  • Scalable modular architecture โ€” optimized for growth and phased expansion.
Category Detail
Rated Output 500 kW / 500 kVA
Input Voltage 480 V AC, 3-phase
Output Voltage 480 V AC, 3-phase
Input Current (Max/Phase) 633 A
Short-Circuit Withstand (Icw) 100 kA
Input THD Less than 3% at full load
Load Power Factor 0.7 leading to 0.5 lagging without derating
Output THD < 2% linear load โ€ข < 3% non-linear load
Crest Factor 3 (with THC < 5%)
Overload Capability 10 min @ 125% โ€ข 60 sec @ 150%
Waveform Pure sine wave
Architecture Modular, N+1 redundant design
Service & commissioning

Included 5ร—8 start-up service ensures proper commissioning, redundancy validation, configuration checks, and operational verification before system handoff.

๐Ÿ› ๏ธ
Engineering support: Need assistance designing a 500 kVA N+1 architecture, battery plant configuration, or upstream breaker coordination at 480 V? Email gps@gruber.com.