APC – Galaxy VS – 150000 – 150 kVA – Three Phase Online UPS

Manufacturer

OEM Part Number

APC-GVSUPS150KFS

GPS Part Number

67-APC-GVSUPS150KFS

Price:

Specifications
Voltage WPC AH/kVA Length Width Height Weight
208VAC N/A 150 Kva 34" 21" 59" 640 lb
Voltage 208VAC
WPC N/A
Amp/H 150 Kva
Length 34"
Width 21"
Height 59"
Weight 640 lb
Schneider Electric Galaxy VS — 150 kW / 480 V (External Batteries) — Start‑Up 5×8

Highly efficient, easy‑to‑deploy 150 kW, 480 V 3‑phase UPS engineered for edge, small/medium data centers, and critical commercial/industrial infrastructure. Designed for external battery systems and includes Start‑Up 5×8 service.

Best‑in‑class power protection with low total cost of ownership — high efficiency, low input distortion, robust short‑circuit withstand, and tight output regulation for sensitive IT and industrial loads.

  • 150 kW / 150 kVA rated power at 480 V 3‑phase
  • External batteries supported — configure runtime to your application
  • Low THDi < 3% at full load
  • High fault tolerance — Icw up to 65 kA
  • Static bypass built‑in
  • Overload capacity 10 min @ 125% and 60 sec @ 150%
Technical Specifications — Galaxy VS 150 kW 480 V
Category Detail
Main Input Voltage 480 V AC, 3‑phase
Max Input Current / Phase 223 A
Input Frequency 40 – 70 Hz
Input THD (Full Load) < 3%
Load Power Factor 0.7 leading to 0.7 lagging (no derating)
Efficiency (Full Load) High‑efficiency operation (spec range: 408…552 V @ 480 V)
Output Voltage 480 V AC, 3‑phase
Rated Power 150 kW / 150 kVA
Max Configurable Power 150 kW / 150 kVA
Bypass Type Built‑in Static Bypass
Crest Factor 2.5
Output Voltage THD < 1% (linear load) and < 5% (non‑linear load)
Output Voltage Tolerance ±1% after 50 ms
Overload Operation 10 minutes @ 125% and 60 seconds @ 150%
Short Circuit Withstand (Icw) 65 kA

Includes Start‑Up 5×8: Deployment/startup service package (5×8 coverage) to help ensure correct commissioning and a clean handoff into production.
External batteries required: Battery cabinets/strings are selected to match your runtime, site constraints, and code requirements.

Why it matters
  • Cleaner input & lower stress — low THDi helps reduce upstream heating and nuisance trips.
  • Tighter output for sensitive loads — low THD and fast regulation support modern IT power supplies and controls.
  • Real overload headroom — ride through inrush events and temporary load spikes.
Why buy from Gruber
  • Pro test & verification — documented inspection and functional verification prior to shipment.
  • Deployment support — help matching external battery solutions to runtime and site constraints.
  • Critical power specialists — real‑world experience across data center and industrial UPS environments.
Compatibility & Variants Matrix
Model / Variant Voltage Battery Type Notes
Galaxy VS 150 kW 480 V 3‑phase External batteries Includes Start‑Up 5×8; built‑in static bypass; configurable runtime via external battery system.

Note: Final configuration (battery cabinet selection, breaker coordination, wiring, and commissioning scope) depends on site requirements and local code. Provide your runtime target and one‑line, and we’ll help align the correct external battery solution.