APC – Galaxy VS – 150000 – 150 kVA – Three Phase Online UPS

Manufacturer

OEM Part Number

APC-GVSUPS150KFS

GPS Part Number

67-APC-GVSUPS150KFS

Price:

Call for Price

Specifications
View Spec Sheet
Voltage AH/kVA Length Width Height Weight
208VAC 150 Kva 34" 21" 59" 640ย lb
Voltage 208VAC
Amp/H 150 Kva
Length 34"
Width 21"
Height 59"
Weight 640ย lb
Schneider Electric Galaxy VS โ€” 150 kW / 480 V (External Batteries) โ€” Startโ€‘Up 5×8

Highly efficient, easyโ€‘toโ€‘deploy 150 kW, 480 V 3โ€‘phase UPS engineered for edge, small/medium data centers, and critical commercial/industrial infrastructure. Designed for external battery systems and includes Startโ€‘Up 5×8 service.

Bestโ€‘inโ€‘class power protection with low total cost of ownership โ€” high efficiency, low input distortion, robust shortโ€‘circuit withstand, and tight output regulation for sensitive IT and industrial loads.

  • 150 kW / 150 kVA rated power at 480 V 3โ€‘phase
  • External batteries supported โ€” configure runtime to your application
  • Low THDi < 3% at full load
  • High fault tolerance โ€” Icw up to 65 kA
  • Static bypass builtโ€‘in
  • Overload capacity 10 min @ 125% and 60 sec @ 150%
Technical Specifications โ€” Galaxy VS 150 kW 480 V
Category Detail
Main Input Voltage 480 V AC, 3โ€‘phase
Max Input Current / Phase 223 A
Input Frequency 40 โ€“ 70 Hz
Input THD (Full Load) < 3%
Load Power Factor 0.7 leading to 0.7 lagging (no derating)
Efficiency (Full Load) Highโ€‘efficiency operation (spec range: 408โ€ฆ552 V @ 480 V)
Output Voltage 480 V AC, 3โ€‘phase
Rated Power 150 kW / 150 kVA
Max Configurable Power 150 kW / 150 kVA
Bypass Type Builtโ€‘in Static Bypass
Crest Factor 2.5
Output Voltage THD < 1% (linear load) and < 5% (nonโ€‘linear load)
Output Voltage Tolerance ยฑ1% after 50 ms
Overload Operation 10 minutes @ 125% and 60 seconds @ 150%
Short Circuit Withstand (Icw) 65 kA

Includes Startโ€‘Up 5×8: Deployment/startup service package (5×8 coverage) to help ensure correct commissioning and a clean handoff into production.
External batteries required: Battery cabinets/strings are selected to match your runtime, site constraints, and code requirements.

Why it matters
  • Cleaner input & lower stress โ€” low THDi helps reduce upstream heating and nuisance trips.
  • Tighter output for sensitive loads โ€” low THD and fast regulation support modern IT power supplies and controls.
  • Real overload headroom โ€” ride through inrush events and temporary load spikes.
Why buy from Gruber
  • Pro test & verification โ€” documented inspection and functional verification prior to shipment.
  • Deployment support โ€” help matching external battery solutions to runtime and site constraints.
  • Critical power specialists โ€” realโ€‘world experience across data center and industrial UPS environments.
Compatibility & Variants Matrix
Model / Variant Voltage Battery Type Notes
Galaxy VS 150 kW 480 V 3โ€‘phase External batteries Includes Startโ€‘Up 5×8; builtโ€‘in static bypass; configurable runtime via external battery system.

Note: Final configuration (battery cabinet selection, breaker coordination, wiring, and commissioning scope) depends on site requirements and local code. Provide your runtime target and oneโ€‘line, and weโ€™ll help align the correct external battery solution.