APC – ACRH301P – InRow Twin-Coil Cooling Unit – 27 kW – 300 mm – New

Manufacturer

OEM Part Number

ACRH301P

GPS Part Number

67-APC-ACRH301P

Categories

Price:

$19,991.65

Specifications
Voltage WPC AH/kVA Length Width Height Weight
200/240 V N/A N/A 43.1" 11.8" 78.4" 441 lb
Voltage 200/240 V
WPC N/A
Amp/H N/A
Length 43.1"
Width 11.8"
Height 78.4"
Weight 441 lb

APC InRow Twin-Coil Cooling Unit — ACRH301P

Cooling: 27 kW Nominal  •  Width: 300 mm  •  Input: 200–240 V, 50/60 Hz

The APC ACRH301P InRow Twin-Coil Cooling Unit is a factory-new Schneider Electric Uniflair indoor unit with 27 kW of nominal cooling capacity. Its 300 mm cabinet installs directly in the rack row, placing cooling close to the IT equipment. Integrated humidification and electric reheat help manage relative humidity and discharge air temperature.

Features
  • 27 kW Nominal Cooling — the InRow Twin-Coil Cooling Unit delivers conditioned air directly to the equipment row.
  • 300 mm Cabinet — fits directly in the rack row to bring cooling closer to the heat load.
  • Twin-Coil Design — paired with variable-speed EC fans for in-row air delivery.
  • Integrated Humidifier & Electric Reheat — helps manage humidity and discharge air temperature.
  • Local Controls & Monitoring — includes a local display and alarms, with building management integration options.
  • Factory-New OEM Equipment — supplied in APC/Schneider Electric packaging with manufacturer warranty and support.

Technical Specifications Detail
Manufacturer APC / Schneider Electric
Model ACRH301P
Product Type Uniflair InRow Twin-Coil Cooling Unit for indoor installation
Condition Factory new
Cooling Capacity 27 kW nominal. Actual capacity depends on configuration and operating conditions.
Power Input 200–240 V, 50/60 Hz. See the nameplate for minimum circuit ampacity and maximum overcurrent protection.
Cabinet Width 300 mm (approximately 11.8 in.)
Fans Variable-speed EC fans
Humidification Integrated humidifier with relative humidity setpoint and alarms
Reheat Integrated electric reheat
Controls & Monitoring Uniflair controller with local display, alarms, and building management integration options
Refrigerant R-410A where equipped with a DX circuit. Confirm circuit and charge requirements in the unit submittal.
Compliance CE and UL at the model-family level. Confirm markings for the ordered configuration.

Options & Accessories
Accessory Detail
Outdoor Condenser APC ACCD / ACCU series for applicable DX configurations. Confirm capacity, site voltage, and piping compatibility.
Water Treatment / Fill Kit Select the humidifier service kit based on the unit configuration and APC water quality requirements.
Leak Detection Optional Uniflair leak detection kit with alarm integration.

Installation Notes

When planning installation for the InRow Twin-Coil Cooling Unit, allow for humidifier water supply and drainage and condensate drainage. Confirm electrical requirements and service clearances in the unit submittal. For applicable DX configurations, verify outdoor condenser selection, refrigerant piping, and controls before installation.