Products

Call Now For Support
1-800-658-5883

APC – Galaxy VS – 30000 – 30 kVA – Three Phase Online UPS

Manufacturer

OEM Part Number

APC-GVSUPS30K0B5FS

GPS Part Number

67-APC-GVSUPS30K0B5FS

Price:

Call for Price

Specifications
View Spec Sheet
Voltage AH/kVA Length Width Height Weight
208VAC 30 Kva 34" 21" 59" 706ย lb
Voltage 208VAC
Amp/H 30 Kva
Length 34"
Width 21"
Height 59"
Weight 706ย lb
Galaxy VS UPS โ€” 30 kW / 30 kVA, 208 V 3-Phase (Battery-Ready, Up to 5ร— 9Ah Smart Modular Strings)

Highly efficient, easy-to-deploy 30 kW, 208 V three-phase UPS delivering best-in-class power protection and low total cost of ownership for edge, small/medium data centers, and commercial & industrial critical loads. Designed for up to 5 internal 9Ah smart modular high-capacity battery strings (VRLA, 480 V system). Supplied without batteries so runtime can be fully customized to site requirements. Includes 5ร—8 start-up service.

Why these fail
  • Runtime miscalculation โ€” battery strings are undersized for real-world load profiles.
  • High harmonic environments โ€” excess THD increases heat and stresses rectifier/inverter stages.
  • Improper commissioning โ€” sync modes and bypass settings not validated under load.
  • Short-circuit exposure โ€” upstream fault levels exceed system withstand ratings.
Our solution
  • Scalable battery architecture โ€” install 1โ€“5 smart modular strings as runtime demands evolve.
  • Low distortion performance โ€” input THD < 3% at full load; output THD < 1% (linear) / < 5% (non-linear).
  • Wide operating window โ€” optimized efficiency from 177โ€ฆ239 V (208 V nominal).
  • Built-in static bypass โ€” seamless transfer during overload or fault events.
  • Embedded network management โ€” integrated Network Management Card 4, EcoStruxureโ„ข ready.
Category Detail
Rated Output 30 kW / 30 kVA
Input Voltage 200 / 208 / 220 V AC, 3-phase
Output Voltage 200 / 208 / 220 V AC, 3-phase
Frequency Input 40โ€“70 Hz โ€ข Output 50/60 Hz (sync to mains)
Input Current (Max/Phase) 107 A
Short-Circuit Withstand (Icw) 65 kA
Power Factor / Cos ฯ† Load PF 0.7 leading to 0.7 lagging (no derating) โ€ข Cos ฯ† 0.99
Harmonics Input THD < 3% โ€ข Output THD < 1% linear / < 5% non-linear
Bypass Built-in static bypass
Overload Capability 10 min @ 125% โ€ข 60 sec @ 150%
Battery System Internal modular VRLA โ€ข 480 V battery system โ€ข Up to 5 strings
End-of-discharge voltage: 384 V DC โ€ข Max discharge current: 81 A
Batteries sold separately
User Interface Touch Screen LCD
Connectivity Embedded Network Management Card 4 โ€ข EcoStruxure Ready
Dimensions (Hร—Wร—D) 77.6 ร— 21.7 ร— 33.3 in (197 ร— 55 ร— 84.7 cm)
Weight 586.4 lb (266 kg)
Included Equipment Dust filter โ€ข Installation manual โ€ข Integrated network management โ€ข 5ร—8 Start-Up Service
Service & coverage

5ร—8 start-up service ensures professional commissioning, configuration validation, and operational verification. Runtime is fully customizable based on the number of installed battery strings (0โ€“5).

๐Ÿ’ก
Design tip: When configuring battery strings, confirm required runtime at actual load (kW), not nameplate kVA, to avoid undersizing.
๐Ÿ› ๏ธ
Tech support: Need help selecting the correct number of battery strings or confirming 200/208/220 V site compatibility? Email
gps@gruber.com.
Gruber Power Services