APC – Galaxy VS – 20000 – 20 kVA – Three Phase Online UPS

Manufacturer

OEM Part Number

APC-GVSUPS20KB4HS

GPS Part Number

67-APC-GVSUPS20KB4HS

Price:

Call for Price

Specifications
View Spec Sheet
Voltage AH/kVA Length Width Height Weight
208VAC 20 Kva 34" 21" 59" 706ย lb
Voltage 208VAC
Amp/H 20 Kva
Length 34"
Width 21"
Height 59"
Weight 706ย lb
Galaxy VS UPS โ€” 20 kW / 20 kVA, 400 V 3-Phase (1ร— 9Ah Smart Modular Battery String, Expandable to 4)

Highly efficient, easy-to-deploy 20 kW, 400 V three-phase UPS designed to deliver best-in-class power protection and low total cost of ownership for edge, small/medium data centers, and commercial & industrial critical loads. Ships with 1 internal 9Ah smart high-capacity modular battery string and supports expansion up to 4 strings for extended runtime (runtime charts available in the Documents tab).

Why these fail
  • Undersizing โ€” growth planning is skipped, leading to overloads and nuisance transfers.
  • Poor power quality โ€” high THD and unstable mains create heat, stress, and premature component aging.
  • Harsh short-circuit environments โ€” installations exceed equipment withstand or bypass capability.
  • Inadequate commissioning โ€” settings, sync modes, and bypass behavior arenโ€™t validated under load.
Our solution
  • High efficiency + low distortion โ€” input THD < 3% at full load; output THD < 1% (linear) / < 3% (non-linear).
  • Wide operating window โ€” maintains efficiency from 340โ€ฆ460 V (400 V nominal range).
  • Built-in static bypass โ€” robust continuity during fault/overload scenarios.
  • Scalable battery architecture โ€” 1 string installed; expand to 4 strings when runtime demands increase.
  • Included 5ร—8 start-up โ€” on-site commissioning support (5 days ร— 8 hours) to validate configuration and operation.
Category Detail
Rated Output 20 kW / 20 kVA
Input Voltage 380 / 400 / 415 V AC, 3-phase
Output Voltage 380 / 400 / 415 V AC, 3-phase
Frequency Input 40โ€“70 Hz โ€ข Output 50/60 Hz (sync to mains) or 50/60 Hz ยฑ0.1% (free-run)
Input Current (Max/Phase) 36 A
Short-Circuit Withstand (Icw) 65 kA
Power Factor / Cos ฯ† Load PF 0.7 leading to 0.7 lagging (no derating) โ€ข Cos ฯ† 0.99
Harmonics Input THD < 3% (full load) โ€ข Output THD < 1% linear / < 3% non-linear load
Bypass Built-in static bypass
Overload Capability 10 min @ 125% โ€ข 60 sec @ 150%
Waveform / Regulation Sine wave โ€ข Output voltage tolerance ยฑ1% after 50 ms
Crest Factor 2.5
Wiring / Connectors Input: Hard-wire 4-wire (3PH + G) or 5-wire (3PH + N + G) โ€ข
Output: Hard-wire 5-wire (3PH + N + G)
Battery (Installed) 1ร— internal 9Ah smart modular battery string
Battery Expansion Expandable up to 4 strings total for increased runtime
Included Service 5ร—8 Start-Up (commissioning support during standard business hours)
๐Ÿ’ก
Maintenance tip: For best lifecycle performance, size the UPS for growth (headroom) and validate harmonic/load profile during commissioningโ€”especially for non-linear IT loads.
๐Ÿ› ๏ธ
Tech support: Need help confirming 380/400/415 V site compatibility, bypass requirements, or battery string sizing? Email gps@gruber.com.
Gruber Power Services