Manufacturer
OEM Part Number
GPS Part Number
Categories
Tags
$23,992.93
| Voltage | WPC | AH/kVA | Length | Width | Height | Weight |
|---|---|---|---|---|---|---|
| 480 V | N/A | N/A | 39.4" | 39.4" | 61.2" | 589 lbs |
| Voltage | 480 V |
| WPC | N/A |
| Amp/H | N/A |
| Length | 39.4" |
| Width | 39.4" |
| Height | 61.2" |
| Weight | 589 lbs |
Complete your compatible precision cooling installation with the APC / Schneider Electric ACCU301 InRow condensing unit. This single-feed outdoor unit works with matched indoor cooling equipment to transfer heat from the IT environment to the outside air.
Supplied as factory-new APC / Schneider Electric equipment, the ACCU301 must be matched to the exact indoor-unit model, electrical supply, refrigerant circuit, and site conditions. Gruber Power Services can assist with equipment selection, installation planning, and applicable manufacturer warranty information.
| Category | Details |
|---|---|
| Product Type | Outdoor air-cooled condensing unit for a compatible APC InRow precision cooling system. |
| Power Configuration | Single-feed input, as identified in the supplied product description. Confirm the complete electrical arrangement using the unit’s nameplate and wiring diagram. |
| Electrical Supply | The supplied description lists 208–230 VAC, three-phase, 60 Hz. Confirm model-specific voltage, phase, frequency, minimum circuit ampacity, and maximum overcurrent protection before ordering. |
| System Compatibility | Select the indoor cooling unit and required controls using the manufacturer’s approved equipment combinations. Compatibility should be confirmed for the exact model and revision. |
| Cooling Performance | Capacity depends on the matched indoor unit, design ambient temperature, entering-air conditions, and refrigerant piping arrangement. Use model-specific performance data for system sizing. |
| Refrigerant Circuit | Confirm refrigerant type, design pressure, connection sizes, field-charge requirements, and supported piping lengths and elevations for the complete system. |
| Fans & Airflow | Confirm fan configuration, speed-control method, discharge direction, and unobstructed airflow clearances in the model-specific installation documentation. |
| Controls & Monitoring | Control wiring and communication requirements depend on the matched indoor cooling unit. Confirm supported alarms, monitoring functions, and required interface hardware. |
| Dimensions & Weight | Request the ACCU301 mechanical drawing and shipping information for exact dimensions, operating weight, lifting points, mounting requirements, and service clearances. |
| Operating Environment | Outdoor installation within the manufacturer’s specified ambient range. Confirm low-ambient requirements, altitude limits, site exposure restrictions, and mounting conditions. |
| Condition & Warranty | Factory-new equipment. Manufacturer warranty duration, coverage, startup requirements, and service terms will be confirmed with the quotation. |
| Option | Details |
|---|---|
| Matched Indoor Cooling Unit | Compatible APC InRow indoor equipment selected using the manufacturer’s approved system combinations. |
| Controls & Interface Hardware | Required control connections and compatible interface equipment for the complete indoor/outdoor system. |
| Mounting & Installation Materials | Site-appropriate supports, field piping, insulation, wiring, disconnects, and protective devices specified for the installation. |
| Startup & Commissioning | Contact Gruber Power Services for assistance identifying required startup procedures and available commissioning support. |