Products

Call Now For Support
1-800-658-5883

APC – SYA8K8P – Symmetra PX – UPS – Refurbished

Manufacturer

OEM Part Number

SYA8K8P

GPS Part Number

59-APC-SYA8K8P

Price:

$17,745.00

Specifications
View Spec Sheet
Voltage AH/kVA Length Width Height Weight
8ย kVA / 6.4ย kW 208/240ย VAC 28.6โ€ณ 19.02โ€ณ 26.4โ€ณ 444.9ย lb
Voltage 8ย kVA / 6.4ย kW
Amp/H 208/240ย VAC
Length 28.6โ€ณ
Width 19.02โ€ณ
Height 26.4โ€ณ
Weight 444.9ย lb

Refurbished UPS โ€” APC/Schneider Electric Symmetraย LX 8ย kVA
(SYA8K8P)

208/240ย V input (4-wire 2PH+N+G) โ€ข
Configurable 120/208 or 120/240ย V output โ€ข
True double-conversion (VFI) โ€ข Modular N+1 tower

Symmetraย LX provides scalable, modular on-line protection in 4ย kVA increments. This 8ย kVA system is fully
reconditioned, cosmetically refreshed, and tested in the USA for reliable, ready-to-deploy service.

What you get
  • Thorough refurbishment โ€” inspection, wear-part replacement to OEM spec, repaint, final QA
  • Comprehensive testing โ€” burn-in, functional verification, alarms cleared
  • Network-ready โ€” LCD console; pre-installed Network Management Cardย 2; 1 SmartSlot free
  • Configured to order โ€” common input/output and bypass arrangements
  • U.S. warranty & support from Gruber Power Services

Technical Specifications โ€” SYA8K8P
Category Detail
Power & Topology 8ย kVA / 6.4ย kW; true double-conversion on-line; sine-wave output; 4ย kVA power increments (N+1 capable)
Input Hard-wire 4-wire (2PH+N+G); 208/240ย VAC; 45โ€“65ย Hz auto-sensing; input PF โ‰ˆ0.98 (full load); input ITHD <7% (full load)
Output Configurable 120/208 or 120/240ย VAC, 4-wire; 47โ€“63ย Hz when syncโ€™d to mains or 50/60ย Hzย ยฑ0.1% free-running; VTHD <5% (full load); crest factor up to 5:1; max output current 37ย A
Bypass Internal bypass (automatic & manual); optional external wrap-around MBB
Short-Circuit / AIC Site-specific; coordinate with upstream/downstream protection and the project one-line
Battery System Lead-acid; included battery modules: 2 ร— SYBT5 (typical recharge โ‰ˆ3ย h); extendable runtime supported
Controls & Comm Multi-function LCD console; Network Management Cardย 2 pre-installed; 1 SmartSlot free; EPO; audible/visible prioritized alarms
Physical 26.4โ€ณ H ร— 19.02โ€ณ W ร— 28.6โ€ณ D; โ‰ˆ444.9ย lb (201.8ย kg); front-service tower
Environment Operating 32โ€“104ย ยฐF (0โ€“40ย ยฐC); 0โ€“95% RH (non-condensing); altitude 0โ€“10,000ย ft; acoustics โ‰ˆ62ย dBA; heat โ‰ˆ3,485ย BTU/h

Battery Cabinets & Options
Accessory Model Notes
Power Module (4ย kVA) SYPM4KP 4ย kVA module; chassis supports N+1 (add module for redundancy)
Battery Module SYBT5 Hot-swappable VRLA; 2 installed in base configuration
Extended-Run Battery Cabinet SYAXR9B9 Tower XR cabinet with 9ร— SYBT5; can chain multiple XR frames for longer runtime
External Maintenance Bypass MBB (site-specific) Wrap-around service bypass option

Notes
  • Configurable outputs support 120/208 or 120/240ย V; verify distribution/backplate needs.
  • Electrical limits and module counts can vary by build; confirm on the project cut-sheet.
  • Batteries/cabinets sold separately unless specified; runtime depends on battery configuration.

Why buy from Gruber
  • Professionally refurbished โ€” Restored in our electronics engineering lab.
  • Ready to install โ€” Plug-and-play functionality with hot-swappable modules.
  • Guaranteed quality โ€” Backed by our no-hassle 1-year full replacement warranty.
Gruber Power Services