Products

Call Now For Support
1-800-658-5883

APC – Symmetra – PD40G6FK1-M – Bypass PDU Cabinet – Tested

Manufacturer

OEM Part Number

PD40G6FK1-M

GPS Part Number

PD40G6FK1-M

Categories

Price:

$4,591.48

Specifications
View Spec Sheet
Voltage AH/kVA Length Width Height Weight
480/208/120 40 kVA 81.0 24.0 36.0 ~1276
Voltage 480/208/120
Amp/H 40 kVA
Length 81.0
Width 24.0
Height 36.0
Weight ~1276

APC Symmetra PX — Bypass PDU Cabinet (40 kVA)

This is the Tested Version.

SKU: PDU-APC-PD40G6FK1-M  |
Type: Floor-standing Bypass + Distribution Cabinet for Symmetra PX 40 kW (integrated
maintenance bypass and dual panelboard distribution). Input 480 V 3-phase, output 120/208 V 3-phase,
three-breaker maintenance bypass (MBB), and two 42-pole panelboards with top and/or bottom feed.

  • Integrated bypass: Three-breaker maintenance bypass for no-downtime service.
  • Power distribution: Dual 42-pole panelboards; top and/or bottom feed outputs.
  • Electrical path: 480 V 3Ï• input → 120/208 V 3Ï• output; 40 kVA frame.
  • Capacity & limits: Max input current 67 A; max total output current 139 A.
  • Cabinet form factor: 81 × 24 × 36 in (HĂ—WĂ—D); ~1,276 lb; cUL/UL 60950 approvals.

Technical Specifications — Symmetra PX 40 kVA Bypass PDU Cabinet (PD40G6FK1-M)
Parameter Detail
Cabinet Type Bypass + Distribution cabinet; floor-standing
Compatible UPS APC Symmetra PX 40 kW (208 V systems)
Input 480 V 3-phase; 60 Hz ± 3 Hz; 1 hardwired feed; max input current 67 A
Output 120/208 V 3-phase; max total output current 139 A
Frame Rating 40 kVA
Maintenance Bypass Three-breaker MBB integrated
Distribution Two 42-pole panelboards; top and/or bottom feed
Dimensions (H×W×D) 81.0 × 24.0 × 36.0 in (2057 × 610 × 914 mm)
Net Weight ≈ 1,276 lb (580 kg)
Approvals cUL Listed; UL 60950
Environment Operating: 32–104 °F (0–40 °C), 0–95% RH; Elevation 0–10,000 ft
Storage: 0–113 °F (0–45 °C), 0–95% RH; Elevation 0–30,000 ft
Color Black
Warranty (mfr.) 1-year repair or replace (typical for cabinet assemblies)

Notes & Replacement

This 40 kVA Bypass PDU cabinet is the standard companion for Symmetra PX 40 kW 208 V systems requiring
integrated maintenance bypass and panelboard distribution. Alternate input/transformer options are available in the
same family for 208→208 and 600→208 applications.

Product Options — Tested vs. Refurbished Cabinets
Option Description Warranty
Tested Input/output verification; breaker/MBB functional test; panelboard pole continuity; indicator/LCD check; safety interlocks verified. 90‑Day
Refurbished Cleaned, serviced cabinet; cosmetic touch-ups; full MBB and distribution re-test; torque & insulation checks documented. 1‑Year

  • Use case: Tie a Symmetra PX 40 kW into building power with integrated maintenance bypass and branch distribution.
  • Serviceability: Three-breaker MBB enables safe, no-downtime UPS maintenance.
  • Install tip: Plan cable routing for top/bottom feed and verify panelboard pole count against branch circuits.

Compatibility & Variants Matrix — Symmetra PX 40 kW Bypass/Distribution
Model Input → Output Distribution Notes
PD40G6FK1-M 480 V 3ϕ → 120/208 V 3ϕ (2) 42-pole panelboards Integrated three-breaker MBB; top/bottom feed.
PD40F6FK1-M 208 V 3ϕ → 208 V 3ϕ (transformer less) Panelboard distribution With maintenance bypass panel; 40 kW frame.
PD40L6FK1-M 600 V 3ϕ → 120/208 V 3ϕ Panelboard distribution With maintenance bypass panel; utility 600 V inputs.
PDRPPNX10-M 208 V 3ϕ → 208 V 3ϕ Panelboard distribution Transformer less Infra Structure PDU with MBB.

Why buy from Gruber
  • Professionally tested — MBB function, breaker operation, and panel continuity verified under load.
  • Exact fit — Purpose-built for Symmetra PX 40 kW line-ups with top/bottom feed flexibility.
  • Documentation — Test reports and torque sheets available with each cabinet.
Gruber Power Services