APC – AP7893 – Metered – 0U – PDU – Tested

Manufacturer

OEM Part Number

AP7893

GPS Part Number

AP7893

Tags

Price:

$249.00

Specifications
View Spec Sheet
Voltage AH/kVA Length Width Height Weight
120 V 5,700 VA 70.00in 2.20in 1.73in 12.02lb
Voltage 120 V
Amp/H 5,700 VA
Length 70.00in
Width 2.20in
Height 1.73in
Weight 12.02lb

APC NetShelter โ€” Metered Rack PDU (AP7893)

This is the Tested Version.

SKU: PDU-APC-AP7893 ย |
Type: 0U vertical, Metered rack PDU for 120/208ย V, 3-phase racks. Delivers up to 5.7ย kVA with a mixed NEMA outlet layout so you can power both 120ย V and 208ย V gear in the same cabinet; 10ย ft (3.05ย m) line cord with NEMAย L21-20P.

  • Outlet mix: 21ย ร—ย NEMAย 5-20R + 6ย ร—ย NEMAย L6-20R (totalย 27).
  • Input: 208ย V 3-phase (Wye) via L21-20P; 10ย ft (3.05ย m) cord.
  • Metered visibility: Local digital ammeter helps balance phases and avoid overloads.
  • Zero-U vertical mount: Preserves rack U-space; toolless mounting kit and brackets included.
  • Data-center ready: UL/cUL listed; FCC Classย A; operating โˆ’5โ€“45ย ยฐC, 5โ€“95% RH (non-condensing).

Technical Specifications โ€” AP7893
Parameter Detail
PDU Type Metered; Zero-U vertical (0U)
Input 208ย V, 3-phase; NEMAย L21-20P; cord length 10ย ft (3.05ย m); 1 power cord
Line Rated / Max Input Current 16ย A line-rated ย |ย  20ย A input limit
Output Voltage 120ย V and 208ย V
Outlets 21ย ร—ย NEMAย 5-20R ย |ย  6ย ร—ย NEMAย L6-20R (totalย 27)
Load Capacity 5,700ย VA (5.7ย kW)
Frequency 50/60ย Hz (47โ€“63ย Hz)
Dimensions (Hร—Wร—D) 70.00 ร— 2.20 ร— 1.73ย in (1778 ร— 56 ร— 44ย mm)
Net Weight 12.02ย lb (5.45ย kg)
Included Hardware Toolless mounting kit; rack mounting brackets; cord-retention bracket(s); installation guide
Certifications / Standards ULย Listed; cULย Listed; Industry Canada ย |ย  ULย 60950-1; CSAย C22.2ย No.ย 60950-1-03; FCC Partย 15 Classย A; ICES-003
Environment Operating: 23โ€“113ย ยฐF (โˆ’5โ€“45ย ยฐC), 5โ€“95% RH; Altitude 0โ€“15,000ย ft ย |ย  Storage: โˆ’13โ€“149ย ยฐF (โˆ’25โ€“65ย ยฐC), 5โ€“95% RH; Altitude 0โ€“50,000ย ft
Warranty (mfr.) 2-year repair or replace

Notes & Replacement

AP7893 is a legacy Metered 0U PDU that APC lists as discontinued (Juneย 14,ย 2022). The recommended current replacement is
AP8863 (NetShelter Metered PDU 2G; 0U; 20ย A; 120/208ย V 3-phase; 24ร— 5-20R + 6ร— L6-20R).

Product Options โ€” Tested vs. Refurbished PDUs
Option Description Warranty
Tested Operationally verified PDU. All outlets checked across phases; cord/plug inspected; meter display verified for correct readout. 90โ€‘Day
Refurbished Cleaned and serviced unit; cosmetic touch-ups as needed; outlets re-verified; meter retested after service. 1โ€‘Year

  • Use case: Mixed 120ย V + 208ย V in the same rack via one 3-phase 0U PDU.
  • Visibility: Local ammeter helps balance phases and avoid breaker trips.
  • Space: Zero-U vertical mounting preserves 19″ rack units for gear.

Compatibility & Variants Matrix
PDU Model Input / Plug Outlet Mix Typical Use / Notes
AP7893 208ย V 3ฯ† / NEMAย L21-20P (10ย ft cord) 21 ร— 5-20R; 6 ร— L6-20R Legacy Metered 0U PDU for mixed 120/208ย V racks; discontinued.
AP8863 (Replacement) 208ย V 3ฯ† / NEMAย L21-20P 24 ร— 5-20R; 6 ร— L6-20R NetShelter Metered PDU 2G; similar mixed-voltage deployments; 0U vertical.

Why buy from Gruber
  • Professionally tested โ€” Load-tested with outlets verified across phases; display confirmed.
  • Exact fit hardware โ€” Ships with the proper 0U vertical mounting solution for NetShelter-style racks.
  • Mixed-voltage flexibility โ€” Power 120ย V IT gear and 208ย V servers from one PDU.