APC – AP7541 – Basic PDU – Tested

Manufacturer

OEM Part Number

AP7541

GPS Part Number

AP7541

Tags

Price:

$483.99

Specifications
View Spec Sheet
Voltage AH/kVA Length Width Height Weight
200 VAC 4,992 VA 63.74in 2.20in 1.73in 10.71-12.72lb
Voltage 200 VAC
Amp/H 4,992 VA
Length 63.74in
Width 2.20in
Height 1.73in
Weight 10.71-12.72lb

APC NetShelter โ€” Basic Rack PDU (AP7541)

This is the Tested Version.

SKU: AP7541 |

Type: 0U vertical, Basic (non-metered) rack PDU for single-phase 200/208/230ย V racks, 30ย A input. Mixed IEC layout โ€” 20ย ร—ย C13 and 4ย ร—ย C19 โ€” on a 10ย ft (3.05ย m) line cord with NEMAย L6-30P. Delivers up to 4,992ย VA (line-rated 24ย A).

  • Outlet mix: 20ย ร—ย IECย 60320ย C13 + 4ย ร—ย IECย 60320ย C19 (totalย 24).
  • Input: 200/208/230ย V single-phase, NEMAย L6-30P; 10ย ft (3.05ย m) cord; 50/60ย Hz.
  • Current & capacity: Input limit 30ย A; line-rated 24ย A; 4,992ย VA total.
  • Zero-U vertical: Preserves rack U-space; includes toolless mounting kit and brackets.
  • Data-center ready: UL/cUL listed, PSE/METI Denan; operating 32โ€“113ย ยฐF (0โ€“45ย ยฐC), 0โ€“95% RH.

Technical Specifications โ€” AP7541
Parameter Detail
PDU Type Basic; Zero-U vertical (0U)
Input 200/208/230ย VAC; NEMAย L6-30P; cord length 10ย ft (3.05ย m); 1 power cord
Current Input current limit 30ย A; line-rated current 24ย A
Output Voltage 200ย V / 208ย V
Outlets 20ย ร—ย IECย 60320ย C13 ย |ย  4ย ร—ย IECย 60320ย C19 (totalย 24)
Load Capacity 4,992ย VA (nominal 5.0ย kVA class)
Frequency 50/60ย Hz
Dimensions (Hร—Wร—D) 63.74 ร— 2.20 ร— 1.73ย in (1619 ร— 56 ร— 44ย mm)
Net Weight 12.28ย lb (5.57ย kg)
Included Hardware Toolless mounting kit; rack mounting brackets; installation guide
Certifications ULย Listed; cULย Listed; PSE; METIย Denan
Standards ULย 60950-1; CSAย C22.2ย No.ย 60950-1-03
Environment Operating: 32โ€“113ย ยฐF (0โ€“45ย ยฐC), 0โ€“95% RH; Altitude 0โ€“10,000ย ft ย |ย  Storage: โˆ’13โ€“149ย ยฐF (โˆ’25โ€“65ย ยฐC), 0โ€“95% RH; Altitude 0โ€“50,000ย ft
Warranty (mfr.) 2-year repair or replace

Notes & Replacement

AP7541 is a current Zero-U Basic PDU (no local metering). If you need local/network metering, see AP8841 (0U, 30ย A, 200/208ย V, 36ย ร—ย C13 + 6ย ร—ย C19). For lower-amp Basic with L6-20P input, see AP7540 (20ย A). For 230ย V regions with a C20 inlet (16ย A) or 32ย A pin-&-sleeve, see AP7552 and AP7553 respectively.

Product Options โ€” Tested vs. Refurbished PDUs
Option Description Warranty
Tested Operationally verified PDU. All IEC outlets checked under load; cord/plug inspected; continuity and ground confirmed. 90โ€‘Day
Refurbished Cleaned and serviced PDU; cosmetic touch-ups as needed; outlets re-verified after service. 1โ€‘Year

    • Use case: Straightforward 200/208/230ย V distribution with mixed C13/C19 outlets; no network features.
    • Space: Zero-U mounting preserves 19″ rack units for gear.
    • Install tip: Balance C13/C19 loads; observe 24ย A continuous (80% of 30ย A) line rating.

Compatibility & Variants Matrix
Model Input / Plug Outlets Rating / Notes
AP7541 200/208/230ย Vย 1ฯ† / NEMAย L6-30P; 10ย ft cord 20ย ร—ย C13; 4ย ร—ย C19 Zero-U Basic; 30ย A max (24ย A line-rated); 4.992ย kVA.
AP7540 208ย V (some regions 200/230ย V) / NEMAย L6-20P; 10ย ft cord 20ย ร—ย C13; 4ย ร—ย C19 Zero-U Basic; 20ย A (โ‰ˆ3.3ย kVA) lower-amp alternative.
AP7552 230ย Vย 1ฯ† / IECย C20 inlet; 10ย ft cord 20ย ร—ย C13; 4ย ร—ย C19 Zero-U Basic; 16ย A (EU/INTL C20 inlet variant).
AP7553 230ย Vย 1ฯ† / IECย 60309 32ย A 2P+E 20ย ร—ย C13; 4ย ร—ย C19 Zero-U Basic; 32ย A high-capacity international variant.

 

Why buy from Gruber
  • Professionally tested โ€” All outlets verified under load; earth/continuity checks documented.
  • Exact fit hardware โ€” Ships with the correct Zero-U mounting kit and brackets.
  • Fleet-ready โ€” Mixed C13/C19 supports servers, blades, and network gear from one PDU.