APC – AP8841 – Power Distribution Unit – Tested

Manufacturer

OEM Part Number

AP8841

GPS Part Number

APC-AP8841

Categories

Price:

$922.99

Specifications
View Spec Sheet
Voltage AH/kVA Length Width Height Weight
208/240 VAC 5.0 kW 1.73in 2.2in 70.51in 15 lbs
Voltage 208/240 VAC
Amp/H 5.0 kW
Length 1.73in
Width 2.2in
Height 70.51in
Weight 15 lbs

APC NetShelter — Metered Rack PDU (AP8841)

This is the Tested Version.

SKU: PDU-APC-AP8841  |
Type: 0U vertical, Metered (2G) rack PDU for 200/208 V single-phase racks. Delivers up to 5.0 kW with a local LCD (amps, volts, kW, kWh) and network monitoring; mixed IEC outlet layout powers varied server/IT loads in the same cabinet.

  • Outlet mix: 36 Ă— IEC 60320 C13 + 6 Ă— IEC 60320 C19 (total 42); compatible with locking IEC cords to reduce accidental disconnects.
  • Input: 200/208 V single-phase, NEMA L6-30P locking plug; cord length 9.84 ft (3.00 m).
  • Metering & alarms: Local LCD plus remote Web/SNMP/CLI; user-defined thresholds; typical metering accuracy ±3%.
  • Zero-U vertical mount: Preserves rack U-space; tool-less mounting in NetShelter-style enclosures included.
  • Data center ready: UL/CSA/IEC listed; operating −5–60 °C, 5–95% RH (non-condensing). Optional environmental sensor port (AP9335T/TH).

Technical Specifications — AP8841
Parameter Detail
PDU Type Metered, 2G; Zero-U vertical (0U)
Input 200–240 VAC acceptable; NEMA L6-30P; cord length 9.84 ft (3.00 m); 1 power cord
Current Input current limit 30 A; line-rated (NA derated) 24 A
Output Voltage 200 V / 208 V
Outlets 36 × IEC 60320 C13  |  6 × IEC 60320 C19 (total 42)
Load Capacity 4,992 VA (nominal 5.0 kW)
Frequency 50/60 Hz
Dimensions (H×W×D) 70.51 × 2.20 × 1.73 in (1791 × 56 × 44 mm)
Net Weight 15.08 lb (6.84 kg)  |  Ship wt. ~18.67 lb (8.47 kg)
Included Hardware Toolless mounting brackets, installation & safety guides, serial configuration cable
Certifications UL 60950-1, CSA C22.2 No. 60950, IEC 60950, VDE, METI Denan / PSE
Environment Operating: 23–140 °F (−5–60 °C), 5–95% RH; Storage: −13–149 °F (−25–65 °C)

Notes & Replacement

AP8841 is an active NetShelter Metered (2G) model with an environmental sensor port (AP9335T/TH optional).
If you need a similar 3-phase metered unit, see AP8861 (208 V 3φ 20 A).

Product Options — Tested vs. Refurbished PDUs
Option Description Warranty
Tested Operationally verified PDU. All IEC outlets checked under load; cord/plug inspected; LCD/network verified for correct readout. 90‑Day
Refurbished Cleaned and serviced PDU; cosmetic touch-ups as needed; outlets and breakers re-verified; LCD and NMC retested. 1‑Year

  • Use case: High-density 200/208 V racks where IEC C13/C19 devices dominate → one 30 A 0U PDU.
  • Visibility: Local LCD plus remote SNMP/Web/CLI for load balance and capacity planning.
  • Space: Zero-U vertical mounting preserves 19″ rack units for gear.

Compatibility & Variants Matrix
PDU Model Input / Plug Outlet Mix Typical Use / Notes
AP8841 200/208 V 1φ / NEMA L6-30P 36 Ă— C13; 6 Ă— C19 Metered 2G 0U PDU for single-phase 200/208 V racks; EcoStruxure-ready.
AP8861 (3φ Variant) 208 V 3φ / NEMA L21-20P 36 Ă— C13; 6 Ă— C19; 2 Ă— NEMA 5-20R Similar metered 2G 0U PDU for 3-phase cabinets needing IEC + limited NEMA outlets.

 

Why buy from Gruber
  • Professionally tested — Outlet branches and breakers verified under load; insulation and ground checks performed.
  • Exact fit hardware — Includes the correct 2U brackets/rails for standard 19″ racks.
  • Data-center friendly — Locking L6-30P input and grouped 5-20R outputs minimize accidental disconnects.

 