APC – AP8841 – Power Distribution Unit – Tested

Manufacturer

OEM Part Number

AP8841

GPS Part Number

APC-AP8841

Tags

Price:

$922.99

Specifications
View Spec Sheet
Voltage AH/kVA Length Width Height Weight
208/240 VAC 5.0 kW 1.73in 2.2in 70.51in 15 lbs
Voltage 208/240 VAC
Amp/H 5.0 kW
Length 1.73in
Width 2.2in
Height 70.51in
Weight 15 lbs

APC NetShelter โ€” Metered Rack PDU (AP8841)

This is the Tested Version.

SKU: PDU-APC-AP8841 ย |
Type: 0U vertical, Meteredย (2G) rack PDU for 200/208ย V single-phase racks. Delivers up to 5.0ย kW with a local LCD (amps, volts, kW, kWh) and network monitoring; mixed IEC outlet layout powers varied server/IT loads in the same cabinet.

  • Outlet mix: 36 ร— IECย 60320ย C13 + 6 ร— IECย 60320ย C19 (totalย 42); compatible with locking IEC cords to reduce accidental disconnects.
  • Input: 200/208ย V single-phase, NEMAย L6-30P locking plug; cord length 9.84ย ft (3.00ย m).
  • Metering & alarms: Local LCD plus remote Web/SNMP/CLI; user-defined thresholds; typical metering accuracy ยฑ3%.
  • Zero-U vertical mount: Preserves rack U-space; tool-less mounting in NetShelter-style enclosures included.
  • Data center ready: UL/CSA/IEC listed; operating โˆ’5โ€“60ย ยฐC, 5โ€“95% RH (non-condensing). Optional environmental sensor port (AP9335T/TH).

Technical Specifications โ€” AP8841
Parameter Detail
PDU Type Metered, 2G; Zero-U vertical (0U)
Input 200โ€“240ย VAC acceptable; NEMAย L6-30P; cord length 9.84ย ft (3.00ย m); 1 power cord
Current Input current limit 30ย A; line-rated (NA derated) 24ย A
Output Voltage 200ย V / 208ย V
Outlets 36 ร— IECย 60320ย C13 ย |ย  6 ร— IECย 60320ย C19 (totalย 42)
Load Capacity 4,992ย VA (nominal 5.0ย kW)
Frequency 50/60ย Hz
Dimensions (Hร—Wร—D) 70.51 ร— 2.20 ร— 1.73ย in (1791 ร— 56 ร— 44ย mm)
Net Weight 15.08ย lb (6.84ย kg) ย |ย  Ship wt. ~18.67ย lb (8.47ย kg)
Included Hardware Toolless mounting brackets, installation & safety guides, serial configuration cable
Certifications ULย 60950-1, CSAย C22.2ย No.ย 60950, IECย 60950, VDE, METIย Denanย /ย PSE
Environment Operating: 23โ€“140ย ยฐF (โˆ’5โ€“60ย ยฐC), 5โ€“95% RH; Storage: โˆ’13โ€“149ย ยฐF (โˆ’25โ€“65ย ยฐC)

Notes & Replacement

AP8841 is an active NetShelter Meteredย (2G) model with an environmental sensor port (AP9335T/TH optional).
If you need a similar 3-phase metered unit, see AP8861 (208ย V 3ฯ† 20ย A).

Product Options โ€” Tested vs. Refurbished PDUs
Option Description Warranty
Tested Operationally verified PDU. All IEC outlets checked under load; cord/plug inspected; LCD/network verified for correct readout. 90โ€‘Day
Refurbished Cleaned and serviced PDU; cosmetic touch-ups as needed; outlets and breakers re-verified; LCD and NMC retested. 1โ€‘Year

  • Use case: High-density 200/208ย V racks where IEC C13/C19 devices dominate โ†’ one 30ย A 0U PDU.
  • Visibility: Local LCD plus remote SNMP/Web/CLI for load balance and capacity planning.
  • Space: Zero-U vertical mounting preserves 19″ rack units for gear.

Compatibility & Variants Matrix
PDU Model Input / Plug Outlet Mix Typical Use / Notes
AP8841 200/208ย V 1ฯ† / NEMAย L6-30P 36 ร— C13; 6 ร— C19 Metered 2G 0U PDU for single-phase 200/208ย V racks; EcoStruxure-ready.
AP8861 (3ฯ† Variant) 208ย V 3ฯ† / NEMAย L21-20P 36 ร— C13; 6 ร— C19; 2 ร— NEMAย 5-20R Similar metered 2G 0U PDU for 3-phase cabinets needing IEC + limited NEMA outlets.

 

Why buy from Gruber
  • Professionally tested โ€” Outlet branches and breakers verified under load; insulation and ground checks performed.
  • Exact fit hardware โ€” Includes the correct 2U brackets/rails for standard 19″ racks.
  • Data-center friendly โ€” Locking L6-30P input and grouped 5-20R outputs minimize accidental disconnects.

 