Products

Call Now For Support
1-800-658-5883

ABB – VE5-1 – Auxiliary Block – Tested

Manufacturer

OEM Part Number

VE5-1

GPS Part Number

20-ABB-VE5-1

Price:

$50.00

Specifications
View Spec Sheet
Voltage AH/kVA Length Width Height Weight
690 V 16 A 2.8" 0.6" 2.7" 1 lbs
Voltage 690 V
Amp/H 16 A
Length 2.8"
Width 0.6"
Height 2.7"
Weight 1 lbs
Accessory โ€” ABB VE5-1
Mechanical/Electrical Interlock โ€ข 2ย N.C. interlocking contacts โ€ข Tested Reclaimed Part

Mechanical and electrical interlock unit for two A-line contactors (reversing, changeover, star-delta starters). Includes 2 built-in N.C. interlocking contacts for coil interlock wiring.

Where itโ€™s used (typical)
  • Reversing contactor pairs (forward/reverse)
  • Changeover and star-delta starter assemblies
  • General mechanical + electrical interlocking of A-series contactors
At-a-Glance Specs
Parameter Detail
Manufacturer ABB
Product ID / EAN 1SBN030110R1000 โ€ข 3471522121370
Function Mechanical & electrical interlock unit (2ย N.C. interlocking contacts)
For use with A9โ€ฆA40, AL9โ€ฆAL40, TAL9โ€ฆTAL40, AX06โ€ฆAX40 contactors (horizontal pairing)
Rated operational voltage (aux circuit) 690ย V (50/60ย Hz)
Rated insulation voltage (Ui) 690ย V (IEC) โ€ข 600ย V (UL/CSA)
Conventional free-air thermal current (Ith) 16ย A (ฮธย =ย 40ย ยฐC)
AC-15 (Ie) 6ย A @ 24/127ย V โ€ข 4ย A @ 220/240ย V โ€ข 3ย A @ 380/400ย V โ€ข 2ย A @ 500ย V โ€ข 2ย A @ 690ย V
DC-13 (Ie) 6ย A @ 24ย V โ€ข 2.8ย A @ 48ย V โ€ข 1ย A @ 72ย V โ€ข 0.55ย A @ 125ย V โ€ข 0.3ย A @ 250ย V
Short-circuit protection (aux) gG fuses 10ย A
Terminals / IP rating Screw terminals โ€ข IP20 (aux terminals)
Mechanical durability 5ย million operations
Power loss 0.1ย W per pole (at rated conditions)
Mounting Rail or plate (not supplied); for two horizontally mounted contactors
Dimensions (H ร— W ร— D) 68ย mm ร— 15ย mm ร— 70ย mm (2.68ย in ร— 0.59ย in ร— 2.76ย in)
Weight 0.076ย kg (โ‰ˆย 0.17ย lb)
Standards / approvals IEC/ENย 60947-5-1 โ€ข ULย 60947-1 โ€ข ULย 60947-5-1 โ€ข CSAย C22.2 (as listed)
Condition Tested pull โ€” cleaned, inspected, verified; light cosmetic wear only
What โ€œTested Reclaimed Partโ€ Means
  • Visual inspection for heat discoloration, terminal condition, cracks, label integrity
  • Mechanical action and latch integrity check
  • Electrical verification: continuity and aux-contact performance per shop procedure
Condition, Options & Warranty
Option Whatโ€™s included Warranty
Tested Pull Cleaned, inspected, verified operation; intact labels; ready to install 90โ€‘Day
Gruber Power Services